Chapter 5 Detailed Function Introductions
P5.10 Operating Timing T7
P5.11 Operating Timing T8
P5.12 Operating Timing T9
P5.13 Operating Timing T10
P5.14 Operating Timing T11
P5.15 Operating Timing T12
P5.16 Operating Timing T13
P5.17 Operating Timing T14
P5.18 Operating Timing T15
Notes:
Define each stage of time during the programmable multi-stage speed operation, the run time varies from 0.0
to 3600 s (for example, if P5.03 is set to min, the unit is min), it is continuous and adjustable. When running
time is set to 0, the speed of this stage is skipped, the inverter will run at the speed of next stage.
P5.19 Step T1 program operating setting
P5.20 Step T2 program operating setting
P5.21 Step T3 program operating setting
P5.22 Step T4 program operating setting
P5.23 Step T5 program operating setting
P5.24 Step T6 program operating setting
P5.25 Step T7 program operating setting
P5.26 Step T8 program operating setting
P5.27 Step T9 program operating setting
P5.28 Step T10 program operating setting
P5.29 Step T11 program operating setting
P5.30 Step T12 program operating setting
P5.31 Step T13 program operating setting
P5.32 Step T14 program operating setting
P5.33 Step T15 program operating setting
Notes:
Specify the acceleration and deceleration time and the running direction of the inverter at each stage. There
are eight combinations with the meanings shown in Table 5-5-1.
Symbol
1F
1r
2F
2r
3F
3r
4F
4r
134
Table 5-5-1 PLC program run setup description
Acc/Dec time 1
Acc/Dec time 2
Acc/Dec time 3
Acc/Dec time 4
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Setting range: 1 F~4 r [1F]
Acc/Dec time
P0.18.P0.19
P2.28, P2.29
P2.30, P2.31
P2.32, P2.33
Direction
F: Forward
r: Reverse
F: Forward
r: Reverse
F: Forward
r: Reverse
F: Forward
r: Reverse