Pd: protection and fault parameters
Function
Parameter name
code
Motor overload
Pd.00
protection mode
selection
Protection
Pd.01
threshold of
motor 1
Protection sensor
Pd.02
input channel of
motor 1
Protection
Pd.03
threshold of
motor 2
Protection sensor
Pd.04
input channel of
motor 2
Electronic
thermal relay
Pd.05
Electrical
protection value
Overload
Pd.06
pre-alarm
detection level
Overload
Pd.07
pre-alarm
detection time
Current
Pd.08
amplitude limit
Current
Pd.09
amplitude limit
level
Overvoltage stall
Pd.10
selection
85
LCD display
0: Failure to actuate
1: Common motor (with
Overload
2: Variable frequency
protection
selection
3: Sensor protection
Protection
threshold of
0.0~10.0V
motor 1
0: Terminal AI1
1: Terminal AI2
Sensor channel
2: Terminal AI3
of motor 1
3: Pulse input
4: Communication setting
Protection
threshold of
0.0~10.0V
motor 2
0: Terminal AI1
1: Terminal AI2
Sensor channel
2: Terminal AI3
of motor 2
3: Pulse input
4: Communication setting
Electronic
20~110%
thermal relay
Overload
pre-alarm
20.0~200.0%
detection level
Overload
pre-alarm
0.0~60.0s
detection time
0: Invalid
1: Valid during
acceleration and
deceleration, and inactive
during constant speed
Current
2: Valid during both
amplitude limit
acceleration and
deceleration and constant
speed
3: Lower operating speed
during overcurrent
Current
amplitude limit
80~180%
level
0: Disable (it is
Overvoltage stall
selection
Setting range
low speed
compensation)
motor (without low
speed compensation)
(immediate protection
once more than the
threshold)
recommended to
choose when
Chapter 4 Parameter Index
Modif
MODBU
Setup
ication
S address
1
×
0E00
10.0V
×
0E01
0
×
0E02
10.0V
0E03
×
0
0E04
×
100%
0E05
160.0%
×
0E06
60.0s
0E07
×
1
0E08
160%
0E09
1
0E0A
×