PC.20 Actual length (m)
0: No display
Notes:
If PC.20 is set to 1, the actual length will be displayed in monitoring state, and all unit indicators will be off.
If it is set to 0, actual length will not be displayed.
PC.21 Power on display
Notes:
PC.21 startup display selection: the function code is used to set the priority display parameters at startup. The
setting values 1~20 correspond to PC.01~PC.20 respectively. When the display control of the display
parameter set is 0 and not displayed, search backwards from the current value set (from the smallest number
to the largest and return to 1 when reaching 20) until the display control of non-0 appears and is displayed.
The priority display parameters at startup are only limited to the parameters of PC.01~PC.20 and are only
valid at startup. When there is a fault, warning or communication CALL displayed, the parameters will be
displayed according to the original priority order and the current priority display will not act.
PC.22 Rotating speed display coefficient
Notes:
PC.22 (Rotating Speed display coefficient) is used to correct the bias of displayed rotating speed and it has no
influence on actual speed.
Rotating Speed Set=Actual Rotating Speed Set ×PC.22 (PG)
Rotating Speed Set=120×Running Frequency ÷ Motor Pole Number×PC.22 (Non-PG)
Reference Rotating Speed=PID Reference Rotating Speed×PC.22 (PG)Reference Rotating Speed=120×Set
Frequency ÷ Motor Pole Number×PC.22 (Non-PG)
PC.23 Linear Speed Coefficient
Notes:
PC.23 linear speed coefficient: It is used to revise the linear speed scale display error and has not effect on the
actual rotating speed.
Linear speed = Running frequency × PC.23 (non PG)
Linear speed = rotate speed × PC.23 (PG)
Reference linear speed= reference frequency* PC.23 (non PG)
Reference linear speed= reference speed × PC.23 (PG)
Tips:
Display Scope:
Linear speed and Reference: 0.000~65.53m/s
Output torque 0~300.0%
Bus voltage
0~1000V
AI3
-10V~10V
157
Figure 5-12-1 Terminal State Indication
Setting range: 0.1 [0]
1: Display
Setting range: 1~20 [1]
Setting range: 0.1~999.9% [100.0%]
Setting Range: 0.1~999.9% [100.0%]
Output power
Output voltage
AI1/AI2
External counting value 0~65530
Chapter 5 Detailed Function Introductions
0~999.9kW
0~999.9V
0.00~10.00V