Continue to run at the operation frequency at the moment of interrupt
StoppingStopping during running (caused by stop command or failure), the inverter not only automatically
records the run time of the current phase, but also records the running frequency at the time of
stoppingstopping. The inverter will restore to the running frequency at the time of stoppingstopping when
restarting, and then continue to the operation in the remaining phases, as shown in Fig. 5-5-5.
Tips:
The difference between way 1 and 2 lies in that way 2 remembers one more running frequency at the time of
stoppingstopping than way 1, and the inverter continues to run from the frequency.
Operation Freq. (Hz)
Run command
P5.02 Saving PLC status when power off
0: Not save
Notes:
Not save
The inverter does not save the PLC operating state when the power is off and restart from the first stage after
the power is on.
Storage: Memory PLC running state at the time of power failure, including power failure time phases,
operating frequency, the run time. Run in PLC interruption running restart mode defined in P5.01.
P5.03 Unit of step time
0: Second
Notes:
This unit is only valid for defining the PLC operating time. The unit of Acc/Dec time in PLC operation is
still second.
P5.04 Operating Timing T1
P5.05 Operating Timing T2
P5.06 Operating Timing T3
P5.07 Operating Timing T4
P5.08 Operating Timing T5
P5.09 Operating Timing T6
133
Continue to operate at the frequency when the inverter stops
f2
d3
a2
f1
a1
T1
T2
Operating time of stage 3
Stopping signal
Figure. 5-5-5 PLC start mode 2
Chapter 5 Detailed Function Introductions
f3
a3
Remnant time of stage 3
Setting range: 0.1 [0]
1: Save
Setting range: 0.1 [0]
1: Minute
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
Setting range: 0.0~3600 [10.0]
f5
f4
a5
a4
Time
T4