AI2 maximum analog
P4.10 AI2 Analog input filter time constant
P4.11 Minimum pulse input value (pulse input terminal)
P4.12 Corresponding physical quantity of input value of
minimum pulse quantity
P4.13 Maximum pulse input value (pulse input
terminal)
P4.14 Corresponding physical quantity of input value of
maximum pulse quantity
P4.15 Pulse input filter time constant (pulse input
terminal)
P4.16 AI3 Minimum analog input value (reserve for
3004GB and below models)
P4.17 Corresponding physical quantity of input value of
AI3 minimum analog
(Reserve for 3004GB and below models)
P4.18 AI3 Maximum analog input value (reserve for
3004GB and below models)
P4.19 Corresponding physical quantity of input value of
AI3 maximum analog
(Reserve for 3004GB and below models)
P4.20 AI3 Analog input filter time constant
(Reserve for 3004GB and below models)
Note 1:
Min/Max virtual value of analog input is the Min/Max virtual value of the input signals. If the actual value
input is smaller than min value, the min value will be treated as the Min virtual value of analog input. If the
actual value input is greater than the max value, the max value will be treated as the Max virtual value of
analog input. The max virtual value of analog input must be greater than the min.
Physical value corresponding to virtual value of analog input: The physical value can be reference frequency,
rotate speed, or pressure, etc.
This series of 35R5GB and above models of inverters are provided with four groups of analog input signals:
analog input terminals AI1, AI2, AI3, pulse; 3004GB and below models of inverters are provided with three
groups of analog input signals: analog input terminals AI1, AI2 and pulse. Users can define input / output
curve for each channel, and can define a total of four groups.
AI1 and AI2 input signals can be 0 ~ 10V voltage signals, or 0 ~ 20mA current signals, are selected by the
users through toggle switch on the control board (SW1 toggle switch is at 1 position, which means when it is
OFF, it corresponds to 0-10V, while when it is on, it corresponds to 0-20mA). The AI3 input signal
corresponds to-10V ~ 10V voltage signal.
Through setting P4.01~P4.04, P4.06~P4.09 and P4.11~P4.14, P4.16~P4.19 can defined two characteristic
linear curves. The positive and negative function is shown in Figure.5-4-1.
Physical value
corresponding to Max
analog value Input%
Physical value
corresponding to Min
analog value Input%
127
Chapter 5 Detailed Function Introductions
Setting range: 0.01~50.00s [0.05s]
Setting range: 0.00 kHz~P4.13 [0.00 kHz]
Setting range: -100.0%~100.0% [0.0%]
Setting range: P4.11~50.00kHz [50.00 kHz]
Setting range: 0.0~100.0% [100.0%]
Setting range: 0.01~50.00s [0.05s]
Setting range: -10.00~P4.18 [0.00V]
Setting range: -100.0%~100.0% [0.0%]
Setting range: P4.16~10.00V [10.00V]
Setting range: -100.0%~100.0% [100.0%]
Setting range: 0.01~50.00s [0.05s]
%
Max analog
Min analog
value (V)
value (V)