Alpha 6000S series User Manual page 84

Table of Contents

Advertisement

Functi
on
Parameter name
code
Set speed
PC.06
(R / min blink)
Running line
PC.07
speed
(m/s)
Set line speed
PC.08
(m / s blink)
Output power
PC.09
(kW)
Output torque
PC.10
(%)
Output voltage
PC.11
(V)
PC.12
Bus voltage (V)
PC.13
AI1 (V)
PC.14
AI2 (V)
3004GB and
below
Reserve
PC.15
35R5GB and
above:
AI3 (V)
Analog PID
PC.16
feedback
(%)
Analog PID
PC.17
setting
(%, blink)
External count
PC.18
value
Terminal state
PC.19
(No unit)
PC.20
Actual length
Power on
PC.21
indication
selection
Speed display
PC.22
coefficient
83
LCD display
Set speed
0: Not displayed 1: Displayed
(R / min blink)
Running line
speed
0: Not displayed 1: Displayed
(m/s)
Set line speed
0: Not displayed 1: Displayed
(m / s blink)
Output power
0: Not displayed 1: Displayed
(kW)
Output torque
0: Not displayed 1: Displayed
(%)
Output voltage
0: Not displayed 1: Displayed
(V)
Bus voltage (V)
0: Not displayed 1: Displayed
AI1 (V)
0: Not displayed 1: Displayed
AI2 (V)
0: Not displayed 1: Displayed
Reserve
-
AI3 (V)
0: Not displayed 1: Displayed
Analog PID
0: Not displayed 1: Displayed
feedback
Analog PID
0: Not displayed 1: Displayed
setting
External count
0: Not displayed 1: Displayed
value
Terminal state
0: Not displayed 1: Displayed
Actual length
0: Not displayed 1: Displayed
Power on
1~20
indication
0.1~999.9%
Mechanical speed = measured
speed × PC.22 (PG)
Mechanical speed = 120 ×
operating frequency ÷ motor
poles × PC.22 (non-PG)
Speed coefficient
Set speed = PID set speed ×
PC.22 (PG)
Set speed = 120 × set
frequency ÷ motor poles ×
PC.22 (non-PG)
Notes: Have no effect on actual
speed
Chapter 4 Parameter Index
Setting range
MOD
Factor
Mo
BUS
y
dif
addres
setting
y
s
0
0D06
0
0D07
0
0D08
0
0D09
0
0D0A
1
0D0B
0
0D0C
0
0D0D
0
0D0E
-
*
0D0F
0
0
0D10
0
0D11
0
0D12
0
0D13
0
0D14
1
0D15
100.0
0D16
%