4.8.3

Handling of high-speed counters

High-speed counters in FX
For details, refer to the following.
4.8.4

Current value update timing and comparison of current value

1. Current value update timing
When pulses are input to an input terminal for a high-speed counter, the high-speed counter executes up-counting or
down-counting. The current values of devices are updated when counting is input.
2. Comparison of the Current value
The following two methods are available to compare and output the current value of a high-speed counter.
1)
Using the comparison instruction (CMP), zone comparison instruction (ZCP) or comparison contact instruction
Use the comparison instruction (CMP), band comparison instruction (ZCP) or contact comparison instruction if the
comparison result is necessary at counting. Use these instructions only when high-speed processing is not
required because these instructions are processed in the operation cycle of the PLC, and operation delay is
generated before the comparison output result is obtained.
If it is necessary to execute comparison to update an output contact with the high-speed counter's changing value,
use comparison instructions for high-speed counters HSCS, HSCR and HSZ.
2)
Using comparison instructions for high-speed counters (HSCS, HSCR or HSZ)
The comparison instructions for high-speed counters (HSCS, HSCR and HSZ) execute a comparison and output
the comparison result during high-speed counting. The number of times these instructions can be used is limited
as shown in the table below.
When an output relay is specified for the comparison result, the comparison result is directly updated at the ON/
OFF status of the output regardless of the output refresh by END instruction.
Mechanical operation delay (about 10 ms) cannot be avoided in a relay output type PLC. Use a transistor output
type PLC.
Instruction
HSCS
HSCR
HSZ
4.8.5

Related devices

1. Devices used to switch the counting direction of 1-phase 1-count input counters
Type
1-phase
1-counting input
120
PLCs operate in the same way as high-speed counters in FX
3G
Limitation in number of instruction
Can be used up to 6 times.
Counter No.
Specifying device
C235
C236
C237
C238
C239
C240
C241
C242
C243
C244
C245
Up-counting
M8235
M8236
M8237
M8238
M8239
M8240
OFF
M8241
M8242
M8243
M8244
M8245
4 Devices in Detail
4.8 High-Speed Counter [C] (FX3G PLCs)
/FX
3U
3UC
→ 4.7.3 Handling of high-speed counters
Down-counting
ON
PLCs.