Mitsubishi Electric FX3G SERIES Programming Manual page 422

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
2)
Sorting result when the instruction is executed with "n = K3 (column No. 3)"
Column No.
Line No.
1
2
3
4
5
Related device
Device
Instruction
M8029
execution complete
Cautions
• Do not change the contents of operands and data while the instruction is executed.
• Before executing the instruction again, set the command input to OFF.
• Limitation in the number of instructions
Only one instruction can be used in a program.
• When the same device is specified in
The source data is overwritten by the data acquired by sorting.
Take special care so that the contents of
420
1
Control number
Height
D
D
4
D
D
+ 1
1
D
D
+ 2
2
D
D
+ 3
5
D
D
+ 4
3
→ For the instruction execution complete flag use method, refer to Subsection 6.5.2.
Name
Turns ON when sorting is completed.
D
S
and
1
D
S
1
14.10 FNC 69 – SORT / SORT Tabulated Data
2
3
Weight
+ 5
D
+ 10
100
20
D
+ 6
+ 11
150
45
D
+ 7
+ 12
180
50
D
+ 8
+ 13
150
50
D
+ 9
+ 14
160
70
Description
D
D
1
are not changed until execution is completed.
14 Handy Instruction – FNC 60 to FNC 69
4
Age
D
+ 15
8
D
+ 16
20
D
+ 17
40
D
+ 18
45
D
+ 19
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents