Mitsubishi Electric FX3G SERIES Programming Manual page 930

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
• FX
PLCs (Extension mode)
3G
Applied instruction
MOV instruction (FNC 12)
BCD instruction (FNC 18)
BIN instruction (FNC 19)
ADD instruction (FNC 20)
SUB instruction (FNC 21)
MUL instruction (FNC 22)
DIV instruction (FNC 23)
INC instruction (FNC 24)
DEC instruction (FNC 25)
WAND instruction (FNC 26)
WOR instruction (FNC 27)
WXOR instruction (FNC 28)
Other applied instructions
928
Execution time at rising edge of input: Execution time in ON status = 5.43 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 5.42 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 5.21 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 6.68 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 6.78 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 7.24 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 7.44 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 3.49 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 3.49 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 6.81 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 6.81 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status = 6.81 μs
Non-execution time: Execution time in OFF status = 0.81 μs
Execution time at rising edge of input: Execution time in ON status + 0.7 μs
Non-execution time: Execution time in OFF status + 0.6 μs
B-5 Execution Time of Pulse Generation Instruction P in Each Applied Instruction
Execution time
B Instruction Execution Time
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents