FNC295 – INITER / Initialize ER
Outline
This instruction initializes extension file registers (ER) to "HFFFF" (<K-1>) in a memory cassette (flash memory) before
executing the SAVER (FNC291) instruction.
Because the INITER (FNC295) instruction is not supported in FX
instruction instead.
1. Instruction format
FNC 295
INITER
P
2. Set data
Operand Type
S
n
3. Applicable devices
Bit Devices
Oper-
and
System User
Type
X Y M T C S D .b KnX KnY KnM KnS
S
n
Explanation of function and operation
1. 16-bit operation (INITER and INITERP)
"n" sectors of extension file registers (ER) in a memory cassette (flash memory) with the same device number as
S
are initialized to "HFFFF" (<K-1>).
Initialization is executed in sectors.
Command
input
FNC295
INITERP
The table below shows the head device number in each sector:
Sector
Head device
number
Sector 0
R0
Sector 1
R2048
Sector 2
R4096
Sector 3
R6144
Sector 4
R8192
Sector 5
R10240
Sector 6
R12288
Sector 7
R14336
Mnemonic
16-bit Instruction
INITER
5 steps
INITERP
Head device number of extension register sector with the same device number as the
extension file register to be initialized
Number of sectors of extension file registers to be initialized
Digit Specification
n
S
Initialized device range
number
ER0 to ER2047
ER2048 to ER4095
ER4096 to ER6143
ER6144 to ER8191
ER8192 to ER10239
ER10240 to ER12287
ER12288 to ER14335
ER14336 to ER16383
33 Extension File Register Control – FNC290 to FNC299
PLCs earlier than Ver.1.30, use INITR (FNC292)
3UC
→ For SAVER (FNC291) instruction, refer to Section 33.2.
→ For INITR (FNC292) instruction, refer to Section 33.3.
Operation Condition
32-bit Instruction
Continuous
Operation
Pulse (Single)
Operation
Description
Word Devices
Special
System User
Index
Unit
T
C D R U \G
V
Z Modify K
Sector
Head device
number
Sector 8
R16384
Sector 9
R18432
Sector 10
R20480
Sector 11
R22528
Sector 12
R24576
Sector 13
R26624
Sector 14
R28672
Sector 15
R30720
33.6 FNC295 – INITER / Initialize ER
Mnemonic
Operation Condition
Data Type
16-bit binary
Others
Con-
Real
Charac-
stant
Number
ter String
H
E
" "
Initialized device range
number
ER16384 to ER18431
ER18432 to ER20479
ER20480 to ER22527
ER22528 to ER24575
ER24576 to ER26623
ER26624 to ER28671
ER28672 to ER30719
ER30720 to ER32767