3. Assignment of mode selection inputs
For using IST instruction, it is necessary to assign inputs having consecutive device numbers as shown below for
mode inputs.
When using non-consecutive inputs or omitting some modes, change the layout by using an auxiliary relay as the
head input for mode specification as shown in the figure below.
- X020: Individual operation mode
- X021: Zero return operation mode
- X022: Stepping operation mode
- X023: Cycle operation mode
- X024: Continuous operation
- X025: Zero return start
- X026: Automatic mode start
- X027: Stop
When inputs do not have
consecutive device numbers
Example:
X030:Individual operation mode
X035:Zero return operation mode
X033:Stepping operation mode
X040:Cycle operation mode
X032:Continuous operation mode
X034:Zero return start
X026:Automatic mode start
X041:Stop
X030
M 0
X035
M 1
X033
M 2
X040
M 3
X032
M 4
X034
M 5
X026
M 6
X041
M 7
In this example, M0 is used as the head input for mode specification.
M8000
FNC 60
RUN
monitor
When only the continuous
operation mode and zero return
operation mode are used
Example:
X030:Zero return operation mode
X031:Continuous operation mode
X032:Automatic mode start zero
return start
X033:Stop
M8000
Individual
operation mode
RUN monitor
X030
Zero return
operation mode
M8000
Stepping
operation mode
Cycle operation
mode
X031
Continuous
operation
X032
Zero return
start
Automatic
mode start
X033
Stop
M 0
S 20
S 29
IST
14 Handy Instruction – FNC 60 to FNC 69
When only the continuous
operation mode and individual
operation mode are used
Example:
X030:Individual operation mode
X031:Continuous operation mode
X032:Automatic mode start
X033:Stop
X030
Does not
M 0
operate
M8000
Zero return
M 1
operation mode
Does not
M 2
operate
Does not
M 3
operate
X031
Continuous
M 4
operation
M8000
Zero return
M 5
start
X032
Automatic
M 6
mode start
X033
M 7
Stop
14.1 FNC 60 – IST / Initial State
Individual
M 0
operation mode
M 1
M 2
M 3
Continuous
M 4
operation
M 5
Automatic
M 6
mode start
M 7
Stop