Program example
In the program example shown below, the value input to D0 is processed by scaling based on the conversion table for
scaling set in R0 and later, and output to D10.
Program
M8000
Operation
Y
Output value
(D10)=35
Point 1
(0,0)
Input value(D0)=7
FNC 269
D0
R0
SCL2
Point 3
(30,100)
Point 4
Point 2
(40,45)
(10,50)
Point 5
(50,30)
Point 6
(60,0)
29 Data Table Operation – FNC250 to FNC269
29.7 FNC269 – SCL2 / Scaling 2 (Coordinate by X/Y Data)
D10
END
Conversion setting data table for scaling
Set item
Number of coordinate points
X coordinate
X
Y coordinate
Setting
Device
contents
R0
K6
Point 1
R1
K0
Point 2
R2
K10
Point 3
R3
K30
Point 4
R4
K40
Point 5
R5
K50
Point 6
R6
K60
Point 1
R7
K0
Point 2
R8
K50
Point 3
R9
K100
Point 4
R10
K45
Point 5
R11
K30
Point 6
R12
K0
685