Set item
Bias speed [Hz]
Max. speed [Hz]
Creep speed [Hz]
Zero return speed [Hz]
Acceleration time [ms]
Deceleration time [ms]
Interruption input of DVIT
*4
instruction
Y0
Y1
*5
Y2
*6
Y3
Individual setting
*1.
The setting range is from 10 to 100,000 Hz in FX
The setting range is from 10 to 200,000 Hz in FX
2HSY-ADP.
The creep speed should satisfy the relationship "Bias speed ≤ Creep speed ≤ Maximum speed."
*2.
*3.
An interrupt input set here cannot be used jointly with a high-speed counter, input interrupt, pulse catch input,
input in SPD (FNC 67) instruction, or interrupt input in DVIT (FNC151) instruction.
*4.
This area can be set only in FX
*5.
Y002 is not available in 14-point and 24-point type FX
*6.
Note that this item can only be set if two FX
Contents of setting
Set the bias speed for each set of output pulses.
Initial value: 0
Set the maximum speed for each set of output pulses.
Initial value: 100,000
Set the creep speed in DSZR (FNC150) instruction for each set of output pulses.
Initial value: 1000
Set the zero point return speed in DSZR (FNC150) instruction for each set of
output pulses.
Initial value: 50000
Set the acceleration time for each set of output pulses.
Initial value: 100
Set the deceleration time for each set of output pulses.
Initial value: 100
*3
Set the interrupt input
for DVIT (FNC151) instruction for each set of output
pulses. Specify a user interrupt command device (M) for a pulse output
destination device not used in DVIT instruction.
Initial setting:
Pulse output destination Y000: X000
Pulse output destination Y001: X001
Pulse output destination Y002: X002
Pulse output destination Y003
Setting for Fixed pulse output destination terminal Y000.
Setting for Fixed pulse output destination terminal Y001.
Setting for Fixed pulse output destination terminal Y002.
Setting for Fixed pulse output destination terminal Y003.
This button displays "Positioning instruction settings" dialog box for setting the
table used in TBL (FNC152) instruction.
→For the setting procedure, refer to the next step.
3G
/FX
PLCs.
3U
3UC
-2HSY-ADP adapters are connected to the FX
3U
2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
Setting range:
X000 to X007, M8460
X000 to X007, M8461
X000 to X007, M8462
*6
: X003
X000 to X007, M8463
/FX
/FX
PLCs.
3U
3UC
PLCs when the pulse output destination is the FX
3U
PLC.
3G
1
Set range
1/10 or less of the
maximum speed
*1
2
*2
10 to 32767
*1
50 to 5000
3
50 to 5000
As shown on the left
4
5
-
3U
6
7
PLC.
3U
8
9