Mitsubishi Electric FX3G SERIES Programming Manual page 872

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Number
FX
Applicable
version
1st analog special adapter
M 8260
Temperature unit selection
M 8261
Not used
M 8262
Not used
M 8263
Not used
M 8264
Not used
M 8265
Not used
M 8266
Not used
M 8267
Not used
M 8268
Not used
M 8269
Not used
2nd analog special adapter
M 8270
Temperature unit selection
M 8271
Not used
M 8272
Not used
M 8273
Not used
M 8274
Not used
M 8275
Not used
M 8276
Not used
M 8277
Not used
M 8278
Not used
M 8279
Not used
3rd analog special adapter
M 8280
Temperature unit selection
M 8281
Not used
M 8282
Not used
M 8283
Not used
M 8284
Not used
M 8285
Not used
M 8286
Not used
M 8287
Not used
M 8288
Not used
M 8289
Not used
4th analog special adapter
M 8290
Temperature unit selection
M 8291
Not used
M 8292
Not used
M 8293
Not used
M 8294
Not used
M 8295
Not used
M 8296
Not used
M 8297
Not used
M 8298
Not used
M 8299
Not used
*1.
In the case of FX
870
Operation and function
-4AD-PT(W)-ADP
FX
3U
*1
Ver.1.30 or later
Ver.1.30 or later
Temperature unit selection
Type-K/-J switching
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Temperature unit selection
Type-K/-J switching
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Temperature unit selection
Type-K/-J switching
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Temperature unit selection
Type-K/-J switching
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
PLCs, all versions are applicable.
3U
37 Operation of Special Devices (M8000 -, D8000 -)
37.2 Supplement of Special Devices (M8000 - and D8000 -)
-4AD-TC-ADP
FX
3U
3U
*1
Ver.1.30 or later
Temperature unit selection
Input sensor selection
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Temperature unit selection
Input sensor selection
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Temperature unit selection
Input sensor selection
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Temperature unit selection
Input sensor selection
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
-4AD-PNK-ADP
*1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents