Program examples
1. Program example 1
In the program example shown below, the BCD data set in X020 to X037 is controlled by the zone from "-1000" to
"+1000", and the controlled value is output to D1 when X000 turns ON.
X000
FNC258
ZONEP
Operation
• In the case of "D0 < 0", "D0 + (-1000)" is output to D1.
• In the case of "D = 0", "0" is output to D1.
• In the case of "D0 > 0", "D0 + 1000" is output to D1.
2. Program example 2
In the program example shown below, the BCD data set in X020 to X057 is controlled by the zone from "-10000" to
"+10000", and the controlled value is output to D11 and D10 when X000 turns ON.
X000
FNC258
DZONEP
Operation
• In the case of "(D1, D0) < 0", "(D1, D0) + (-10000)" is output to (D11,
D10).
• In the case of "(D1, D0) = 0", the "0" is output to (D11, D10).
• In the case of "(D1, D0) > 0", "(D1, D0) + 10000" is output to (D11,
D10).
FNC 19
K4X020
BIN
K-1000
K1000
D0
FNC 19
K8X020
DBIN
K-10000 K10000
D0
29 Data Table Operation – FNC250 to FNC269
29.3 FNC258 – ZONE / Zone Control
D0
D1
END
-1000
D0
D10
END
-10000
Output
1000
0
Input
1000
-1000
Output
10000
0
Input
10000
-10000
671