Mitsubishi Electric FX3G SERIES Programming Manual page 439

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Related devices
Device
Instruction execution com-
M8029
Cautions
1. Time to update the 4-digit seven-segment display
The scan time (operation cycle) multiplied by 12 is required to update (one or two sets of) the 4-digit display.
2. Operation when the command input turns OFF
While the command input is ON, the operation is repeated.
When the command contact is set to OFF in the middle of an operation, the operation is paused. When the command
contact is set to ON again, the operation is started from the beginning.
3. Number of occupied devices
When one set of 4 digits is used:
When two sets of 4 digits are used:
4. Scan time (operation cycle) and the display timing
SEGL instruction is executed in synchronization with the scan time (operation cycle) of the PLC.
For achieving a series of display, the scan time of the PLC should be 10 ms or more.
If the scan time is less than 10 ms, use the constant scan mode so that the scan time exceeds 10 ms.
5. Output type of the PLC
Use a transistor output type PLC.
→ For the instruction execution complete flag use method, refer to Subsection 6.5.2.
Name
Turns ON when output of 4 digits is finished.
plete flag
1 device is occupied from the head device specified in
8 devices are occupied from the head device specified in
number of digits is smaller than 4, unused devices cannot be used for any
other purpose.
2 devices are occupied from the head device specified in
Twelve devices are occupied from the head device specified in
if the number of digits is smaller than 4, unused devices cannot be used for
any other purpose.
15 External FX I/O Device – FNC 70 to FNC 79
15.5 FNC 74 – SEGL / Seven Segment With Latch
Description
11
12
13
S
.
14
D
. Even if the
S
.
D
. Even
15
16
17
18
19
20
437