Mitsubishi Electric FX3G SERIES Programming Manual page 542

Programmable controllers
Hide thumbs Also See for FX3G SERIES:
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Related instruction
Instruction
DIS (FNC144)
Errors
An operation error occurs in the following cases; The error flag M8067 turns ON, and the error code is stored in
D8067.
• When
S
• When "n" is outside the range from "0 to 4" (error code: K6706)
Program example
In the program below, the low-order 4 bits of D0 to D2 are combined and stored in D10 when X000 turns ON.
X000
b15
D0
0
0
0
0
D1
0
0
0
0
D2
0
0
0
0
540
Separates 16-bit data in 4-bit units.
to
S
+n are outside the specified device range (error code: K6706)
FNC143
D0
D10
UNIP
b4 b3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
1
0
Combined data
19.4 FNC143 – UNI / 4-bit Linking of Word Data
Description
K3
END
b0
b15
D10
0
1
0
0
0
0
1
0
1
Because "n" is "K3",
they are set to "0".
19 Data Operation 2 – FNC140 to FNC149
b12b11
b4 b3
0
1
0
0
1
0
1
0
1
b0
0
0
0
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc series

Table of Contents