APPENDIX F
PRODUCT SETUP>COMMUNICATION SETTINGS >DNP3 SLAVE (CONT.)
DNP3 SLAVE 1 > DNP3 SLAVE 2 > DNP3 SLAVE 3
SETTING DESCRIPTION
Scale for power
Scale for energy
Other Scale factor
Default deadband for Current Analog
Input points to trigger unsolicited
responses
Default deadband for Voltage Analog
Input points to trigger unsolicited
responses
Default deadband for Power Analog
Input points to trigger unsolicited
responses
Default deadband for Energy Analog
Input points to trigger unsolicited
responses
Default deadband for Other Analog
Input points to trigger unsolicited
responses
Size (in bytes) for message
fragmentation
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
Size customization and change of
DNP Binary Inputs point list
DNP NOTES
Note 1: Scale Factor
Note 2: Binary Input Block Selection:
GEK-113285A
NAME
DEFAULT VALUE
Power Scale Factor
1
Energy Scale Factor
1
Other Scale Factor
1
Current Deadband
30000
Voltage Deadband
30000
Power Deadband
30000
Energy Deadband
30000
Other Deadband
30000
Msg Fragment Size
240
Binary Input Block 1
CTL EVENTS 1-16 N/A
Binary Input Block 2
CTL EVENTS 17-32 N/A
Binary Input Block 3
CTL EVENTS 33-48 N/A
Binary Input Block 4
CTL EVENTS 49-64 N/A
Binary Input Block 5
CTL EVENTS 65-80 N/A
Binary Input Block 6
CTL EVENTS 81-96 N/A
CTL EVENTS 97-
Binary Input Block 7
112
CTL EVENTS 113-
Binary Input Block 8
128
Binary Input Block 9
SWITCHGEAR 1-8 N/A
SWITCHGEAR 9-
Binary Input Block 10
16
Note that a scale factor of 0.1 is equivalent to a multiplier of 10 (i.e. the value will be 10 times
[NOT USED, CTL EVENTS 1-16, CTL EVENTS 17-32, CTL EVENTS 33-48,CTL EVENTS 49-
64, CTL EVENTS 65-80, CTL EVENTS 81-96, CTL EVENTS 97-112, CTL EVENTS 113-128,
SWITCHGEAR 1-8, SWITCHGEAR 9-16]
G650 Generator Protection & Control System
F.1 FACTORY DEFAULT SETTINGS
STEP
RANGE
[0.00001-0.0001-0.001-
N/A
0.01-0.1-1-10-100-1000]
[0.00001-0.0001-0.001-
N/A
0.01-0.1-1-10-100-1000]
[0.00001-0.0001-0.001-
N/A
0.01-0.1-1-10-100-1000]
N/A
[0 : 65535]
N/A
[0 : 65535]
N/A
[0 : 65535]
N/A
[0 : 65535]
N/A
[0 : 65535]
1 byte
[30 : 2048]
[See DNP note2]
[See DNP note2]
[See DNP note2]
[See DNP note2]
[See DNP note2]
[See DNP note2]
N/A
[See DNP note2]
N/A
[See DNP note2]
[See DNP note2]
N/A
[See DNP note2]
USER
VALUE
F
F-3