GE Multilin G650 Manual page 100

Generator protection & control system
Hide thumbs Also See for Multilin G650:
Table of Contents

Advertisement

4 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES 4.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE
Table 4–19: ACTUAL VALUES RELATED TO RECORDING FUNCTIONS IN THE RECORDS STATUS MENU:
RECORD
STATUS
Fault Reports
Control Events
Oscillography
Data Logger
Demand
Energy
Breaker Maintenance
4.1.9.3 METERING
The Metering menu includes all the measurements available in the device. Primary and secondary values, and also the
data related to the recording functions in the relay.
Table 4–20: GENERAL OVERVIEW OF METERING MENU:
METERING
Primary Values
Secondary Values
Phasor Diagram
Frequency
4.1.9.4 INPUTS/OUTPUTS
The Inputs/Outputs menu includes all the inputs and outputs signals available in the device. Contact and virtual type.
Table 4–21: GENERAL OVERVIEW OF INPUTS/OUTPUTS MENU:
INPUTS/
OUTPUTS
Contact Inputs
Contact Output Status
Contact Outputs
Operates
Contact Outputs
Resets
IO Board Status
Virtual Inputs
Virtual Outputs
Analog Inputs
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
GEK-113285A
This menu shows the fault report status signals, as fault report trigger,
fault date, fault type and location, besides the fault report number.
Status of the control events (if the signal configured to launch the control
event is active or not).
Status of signals related to oscillography recording, such as status or
digital channels, oscillography trigger, number of records available, etc.
Data logger information about oldest and newest sample time stamp,
and number of channels and days configured in data logger settings.
Demand trigger and reset inputs status.
Freeze, unfreeze and reset input signals for energy counters.
All signals related to breaker maintenance, such as number of openings,
2
closings, (KI)
t counters, alarm signal for (KI)
Primary values measurements for currents, voltages, power, energy and
demand
Secondary values measurements for currents, voltages and power.
Current, voltage and sequence components.
Line and Bus frequencies.
Status of digital inputs in the Relay for each board according to the relay
model.
Status of digital outputs in the Relay for each board according to the relay
model.
Status (activated or not) of the variables used to operate a contact
output.
To
configure
Configuration>Outputs" menu.
Status (activated or not) of the variables used to reset a contact output.
To configure these signals go to "Setpoint>Relay Configuration>Outputs"
menu. This output reset Command will only be effective if the "latch"
option has been Selected for the "Output Type" setting on the I/O board,
thus when the contact output has been configured to emulate function 86
(latching relay).
Status of I/O boards. This status provides if the hardware it is OK (boards
matching relay model, correctly inserted in their tracks, in good state and
communicating through the internal CAN Bus).
Status of Virtual inputs latched (32) and self-reset (32).
Status of virtual outputs (configured in PLC Editor). Up to 512.
Measurements coming from analog inputs (DCMA)
G650 Generator Protection & Control System
2
t, etc.
these
signals
go
to
"Setpoint>Relay
4
4-25