APPENDIX B
ADDRESS BIT
NAME
Ajustes Desequilibrio de Generador Grupo 2 - Generator Unbalance 2 Settings
0x42A9
Function
0x42AA
Gen Unbal Inom
0x42AC
Gen Unbal Stg1 Pkp
0x42AE
Gen Unbal Stg1 K
0x42B0
Gen Unbal Stg1 Tmin
0x42B2
Gen Unbal Stg1 Tmax
0x42B4
Gen Unbal Stg1 K-Rst
0x42B6
Gen Unbal Stg2 Pkp
0x42B8
Gen Unbal Stg2 Delay
0x42BA
Snapshot Events
0x42C4
Confirmation address
Ajustes Desequilibrio de Generador Grupo 3 - Generator Unbalance 3 Settings
0x42C5
Function
0x42C6
Gen Unbal Inom
0x42C8
Gen Unbal Stg1 Pkp
0x42CA
Gen Unbal Stg1 K
0x42CC
Gen Unbal Stg1 Tmin
0x42CE
Gen Unbal Stg1 Tmax
0x42D0
Gen Unbal Stg1 K-Rst
0x42D2
Gen Unbal Stg2 Pkp
0x42D4
Gen Unbal Stg2 Delay
0x42D6
Snapshot Events
0x42E0
Confirmation address
Ajustes Voltios/ Hercios Grupo 1 - Volts per Hertz 1 Settings(Enhanced models only)
0x42E1
Function
0x42E2
V/Hz Source
0x42E3
V/Hz Minimum Voltage
0x42E5
V/Hz Pickup Level
0x42E7
V/Hz Curve
0x42E8
V/Hz TD Multiplier
0x42EA
V/Hz Reset Delay
0x42EC
Snapshot Events
0x42F6
Confirmation address
Ajustes Voltios/ Hercios Grupo 2 - Volts per Hertz 2 Settings(Enhanced models only)
0x42F7
Function
0x42F8
V/Hz Source
0x42F9
V/Hz Minimum Voltage
0x42FB
V/Hz Pickup Level
0x42FD
V/Hz Curve
GEK-113285A
FORMAT STEP MODE LENGTH MISCELLANEOUS
F012
1
F003
1
F003
1
F003
1
F003
1
F003
1
F003
1
F003
1
F003
1
F012
1
F012
1
F003
1
F003
1
F003
1
F003
1
F003
1
F003
1
F003
1
F003
1
F012
1
F012
1
F012
1
F003
1
F003
1
F012
1
F003
1
F003
1
F012
1
F012
1
F012
1
F003
1
F003
1
F012
1
G650 Generator Protection & Control System
R/W
1
0=DISABLED
1=ENABLED
R/W
2
[0.00 , 10.00] A
R/W
2
[0.00 , 100.00] %
R/W
2
[0.00 , 100.00]
R/W
2
[0.0 , 1000.0] s
R/W
2
[0.0 , 1000.0] s
R/W
2
[0.0 , 1000.0]
R/W
2
[0.00 , 100.00] %
R/W
2
[0.0 , 1000.0] s
R/W
1
0=DISABLED
1=ENABLED
W
1
R/W
1
0=DISABLED
1=ENABLED
R/W
2
[0.00 , 10.00] A
R/W
2
[0.00 , 100.00] %
R/W
2
[0.00 , 100.00]
R/W
2
[0.0 , 1000.0] s
R/W
2
[0.0 , 1000.0] s
R/W
2
[0.0 , 1000.0]
R/W
2
[0.00 , 100.00] %
R/W
2
[0.0 , 1000.0] s
R/W
1
0=DISABLED
1=ENABLED
W
1
R/W
1
0=DISABLED
1=ENABLED
R/W
1
0=PHASES
1=AUX VOLTAGE
R/W
2
[30.00 , 500.00] V
R/W
2
[0.80 , 4.00] pu
R/W
1
0=DEFINITE TIME
1=CURVE A
2=CURVE B
3=CURVE C
R/W
2
[0.05 , 600.00]
R/W
2
[0.0 , 900.0] s
R/W
1
0=DISABLED
1=ENABLED
W
1
R/W
1
0=DISABLED
1=ENABLED
R/W
1
0=PHASES
1=AUX VOLTAGE
R/W
2
[30.00 , 500.00] V
R/W
2
[0.80 , 4.00] pu
R/W
1
0=DEFINITE TIME
1=CURVE A
B.7 MEMORY MAP
B
B-129