Table of Contents
Table of Contents
5
Cautions and Warnings
13
Introduction to the Ur
14
1.2 Ur Overview
15
Hardware Architecture
15
Software Architecture
16
1.3 Enervista Ur Setup Software
17
Pc Requirements
17
Configuring the G60 for Software Access
19
Using the Quick Connect Feature
21
Connecting to the G60 Relay
27
1.4 Ur Hardware
28
Mounting and Wiring
28
1.5 Using the Relay
29
Faceplate Keypad
29
Relay Passwords
30
Commissioning
31
Monitoring
33
Inputs
34
Ordering
35
Communications
36
Inter-Relay Communications
38
Replacement Modules
39
2.2 Specifications
42
Protection Elements
42
User-Programmable Elements
46
Type Tests
53
Approvals
54
3.1 Description
55
Panel Cutout
55
Module Withdrawal and Insertion
60
Rear Terminal Layout
62
3.2 Wiring
64
Typical Wiring
64
Dielectric Strength
65
Ct/Vt Modules
66
Process Bus Modules
68
Transducer Inputs/Outputs
76
Rs232 Faceplate Port
77
Cpu Communication Ports
77
Irig-B
81
Direct Input/Output Communications
82
Description
82
Fiber: Led and Eled Transmitters
84
Fiber-Laser Transmitters
84
Interface
85
Rs422 Interface
88
Rs422 and Fiber Interface
90
And Fiber Interface
90
Ieee C37.94 Interface
91
C37.94Sm Interface
93
Managed Ethernet Switch Modules
95
Overview
95
Managed Ethernet Switch Module Hardware
95
Managed Switch Led Indicators
96
Configuring the Managed Ethernet Switch Module
96
Uploading G60 Switch Module Firmware
99
Ethernet Switch Self-Test Errors
101
Human Interfaces
103
Enervista Ur Setup Software Interface
103
Introduction
103
Creating a Site List
103
Enervista Ur Setup Overview
103
Enervista Ur Setup Main Window
105
Extended Enervista Ur Setup Features
106
Settings Templates
106
Securing and Locking Flexlogic™ Equations
110
Settings File Traceability
112
Faceplate Interface
115
Faceplate
115
Led Indicators
116
Custom Labeling of Leds
119
Display
125
Keypad
125
Breaker Control
125
Menus
126
Changing Settings
128
Settings
128
Overview
133
Settings Main Menu
133
Introduction to Elements
136
Introduction to Ac Sources
137
Product Setup
140
Security
140
Display Properties
144
Clear Relay Records
146
Communications
147
Modbus User Map
168
Real Time Clock
169
User-Programmable Fault Report
170
Oscillography
171
Data Logger
173
User-Programmable Leds
174
User-Programmable Self Tests
177
Control Pushbuttons
178
User-Programmable Pushbuttons
179
Flex State Parameters
184
User-Definable Displays
185
Direct Inputs/Outputs
187
Teleprotection
195
Installation
195
5.3 Remote Resources
197
Remote Resources Configuration
197
System Setup
198
Ac Inputs
198
Power System
199
Signal Sources
200
Disconnect Switches
207
Flexcurves
210
Phasor Measurement Unit
217
Flexlogic
233
Introduction to Flexlogic
233
Flexlogic™ Rules
244
Flexlogic™ Evaluation
244
Flexlogic™ Example
245
Flexlogic Equation Editor
249
Flexlogic Timers
249
Flexelements
251
Non-Volatile Latches
255
Grouped Elements
256
Overview
256
Setting Group
256
Distance
256
Stator Differential
256
Phase Current
256
Power Swing Detect
265
Stator Differential
273
Neutral Current
287
Ground Current
294
Negative Sequence Current
301
Generator Unbalance
304
Split Phase Protection
308
Voltage Elements
310
Loss of Excitation
320
Accidental Energization
322
Sensitive Directional Power
324
Stator Ground
327
Control Elements
333
Overview
333
Trip Bus
333
Setting Groups
335
Selector Switch
336
Underfrequency
342
Overfrequency
343
Frequency Rate of Change
344
Frequency Out-Of-Band Accumulation
346
Synchrocheck
348
Digital Elements
353
Digital Counters
356
Monitoring Elements
358
Inputs/Outputs
359
Contact Inputs
359
Virtual Inputs
361
Contact Outputs
362
Virtual Outputs
364
Remote Devices
365
Remote Inputs
366
Remote Double-Point Status Inputs
367
Remote Outputs
367
Resetting
368
Direct Inputs and Outputs
369
Teleprotection Inputs and Outputs
372
Iec 61850 Goose Analogs
374
Iec 61850 Goose Integers
375
Transducer Inputs and Outputs
376
Dcma Inputs
376
Rtd Inputs
377
Rrtd Inputs
379
Dcma Outputs
383
Testing
387
Test Mode
387
Force Contact Inputs
388
Force Contact Outputs
389
Phasor Measurement Unit Test Values
390
Actual Values
393
Overview
393
Actual Values Main Menu
393
Status
396
Contact Inputs
396
Virtual Inputs
396
Remote Inputs
396
Remote Double-Point Status Inputs
397
Teleprotection Inputs
397
Contact Outputs
397
Virtual Outputs
398
Remote Devices
398
Digital Counters
399
Selector Switches
399
Flex States
399
Ethernet
399
Direct Inputs
400
Direct Devices Status
400
Iec 61850 Goose Integers
401
Egd Protocol Status
401
Teleprotection Channel Tests
402
Ethernet Switch
402
6.3 Metering
403
Metering Conventions
403
Stator Differential
406
Sources
406
Synchrocheck
410
Tracking Frequency
410
Frequency Rate of Change
411
Frequency Out-Of-Band Accumulation
411
Flexelements
411
Iec 61580 Goose Analog Values
412
Sensitive Directional Power
412
Stator Ground
413
Volts Per Hertz
413
Restricted Ground Fault
413
Phasor Measurement Unit
413
Transducer Inputs and Outputs
414
Records
415
User-Programmable Fault Reports
415
Event Records
415
Oscillography
415
Data Logger
416
Phasor Measurement Unit Records
416
Product Information
417
Model Information
417
Firmware Revisions
417
Commands and
419
Commands
419
Commands Menu
419
Virtual Inputs
419
Clear Records
420
Set Date and Time
420
Relay Maintenance
421
Phasor Measurement Unit One-Shot
422
7.2 Targets
424
Targets Menu
424
Target Messages
424
Relay Self-Tests
424
Security
429
Password Security
429
Overview
429
Password Security Menu
430
Local Passwords
430
Remote Passwords
431
Access Supervision
431
Dual Permission Security Access
432
Settings Security
434
Settings Templates
434
Securing and Locking Flexlogic™ Equations
438
Settings File Traceability
440
Enervista Security Management System
443
Overview
443
Enabling the Security Management System
443
Adding a New User
443
Modifying User Privileges
444
Theory of Operation
447
Phase Distance through Power Transformers
447
Description
447
Example
450
Application of
453
Setting Example
453
Description
453
System Setup
453
Power System
454
Signal Sources
454
Stator Differential
455
Generator Unbalance
455
Loss of Excitation
456
Reverse Power
456
System Backup Overcurrent
457
Backup Distance
458
Stator Ground Fault
459
Overexcitation
462
Inputs/Outputs
463
Frequency
464
Accidental Energization
464
Flexlogic
465
Phase Distance through Power Transformers
466
Overview
466
Example
467
Commissioning
469
Testing
469
Testing Underfrequency and Overfrequency Elements
469
Parameter Lists
471
Flexanalog Items
471
A.1.1 Flexanalog Items
471
Flexinteger Items
481
A.1.2 Flexinteger Items
481
B.1 Modbus Rtu Protocol
483
B. Modbus
483
Communications
483
Introduction
483
Physical Layer
483
Data Link Layer
483
B.1.1 Introduction
483
Algorithm
484
B.1.4 Crc-16 Algorithm
484
Modbus Function Codes
485
Supported Function Codes
485
Read Actual Values or Settings (Function Code 03/04H
485
Execute Operation (Function Code 05H
485
Execute Operation (Function Code 05H
486
Store Single Setting (Function Code 06H
486
Store Multiple Settings (Function Code 10H
487
Exception Responses
487
File Transfers
488
Obtaining Relay Files Via Modbus
488
Modbus Password Operation
489
Memory Mapping
490
Data Formats
547
Iec 61850
567
Communications
567
Introduction
567
Communication Profiles
567
C.1.1 Introduction
567
Overview
567
Server Data Organization
568
Overview
568
Ggio1: Digital Status Values
568
Ggio2: Digital Control Values
568
Ggio3: Digital Status and Analog Values from Received Goose Datac-2
568
Ggio4: Generic Analog Measured Values
568
C.2.1 Overview
568
Mmxu: Analog Measured Values
569
Protection and Other Logical Nodes
569
Server Features and Configuration
571
Buffered/Unbuffered Reporting
571
File Transfer
571
Timestamps and Scanning
571
Logical Device Name
571
Location
571
Logical Node Name Prefixes
572
Connection Timing
572
Non-Iec 61850 Data
572
Communication Software Utilities
572
Generic Substation Event Services: Gsse and Goose
573
Overview
573
Gsse Configuration
573
Fixed Goose
573
Configurable Goose
573
C.4.1 Overview
573
Ethernet Mac Address for Gsse/Goose
575
Gsse ID and Goose ID Settings
576
Iec 61850 Implementation Via Enervista Ur Setup
577
Overview
577
C.5.1 Overview
577
Configuring Iec 61850 Settings
578
About ICD Files
579
Creating an ICD File with Enervista Ur Setup
583
About Scd Files
583
Importing an Scd File with Enervista Ur Setup
586
Acsi Conformance
588
Acsi Basic Conformance Statement
588
Acsi Models Conformance Statement
588
Acsi Services Conformance Statement
589
Logical Nodes
592
Logical Nodes Table
592
Iec 60870-5-104
595
Interoperability Document
595
D.1.1 Interoperability Document
595
Iec 60870-5-104 Point List
603
Dnp Communications
605
Device Profile Document
605
Dnp V3.00 Device Profile
605
E.1.2 Implementation Table
608
Dnp Point Lists
612
Binary Input Points
612
Binary and Control Relay Output
613
Counters
614
E.2.3 Counters
614
Analog Inputs
615
E.2.4 Analog Inputs
615
Change Notes
617
F.1.1 Revision History
617
Changes to the G60 Manual
618
Abbreviations
622
Standard Abbreviations
622
F.2.1 Standard Abbreviations
622
Warranty
624
Ge Multilin Warranty
624
F.3.1 Ge Multilin Warranty
624
Advertisement
Advertisement
Related Products
GE Multilin g60
GE Multilin G650
GE G6S28TSLSS
GE GFDS350GL
GE GLD7400R
GE Profile GSHS3KGZSS
GE GFSS6PKBSS
GE GSL25JGCLB
GE GSC3500R
GE GLDA696MSS
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL