C.3 IMPLEMENTATION TABLE
b) IMPLEMENTATION TABLE (SHEET 2 OUT OF 3)
OBJECT
Object
Variation
No.
No.
21
0
22
0
30
0
30
1
C
30
2
30
3
30
4
32
0
32
1
32
2
32
3
32
4
34
0
34
1
Note 1: A default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans.
Note 2: For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28,
respectively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01
(for change-event objects, qualifiers 17 or 28 are always responded).
Note 3: Cold restarts are implemented the same as warm restarts – The G650 is not restarted, but the DNP process is restarted.
C-8
Description
Frozen Counter - All Variations
Counter Change Event - All
Variations
Analog Input - All Variations
32-Bit Analog Input
See Note 1
16-Bit Analog Input
32-Bit Analog Input without Flag
16-Bit Analog Input without Flag
Analog Change Event - All Variations 1
32-Bit Analog Change Event without
Time
See Note 1
16-Bit Analog Change Event without
Time
32-Bit Analog Change Event with
Time
16-Bit Analog Change Event with
Time
Analog Input Reporting Deadband
16-Bit Analog Input Reporting
Deadband
See Note 1
G650 Generator Protection & Control System
REQUEST
Function Codes
Qualifier Codes (hex) Function Codes Qualifier Codes
(dec)
1
(read)
06
(no range, or all)
06
(no range, or all)
1
(read)
07,08
(limited qty)
06
(no range, or all)
1
(read)
00,01
(start-stop)
22
(assign class)
07,08
(limited qty)
17,28
(index)
000,01
(start-stop)
1
(read)
06
(no range, or all)
22
(assign class)
07,08
(limited qty)
17,28
(index)
00,01
(start-stop)
1
(read)
06
(no range, or all)
22
(assign class)
07,08
(limited qty)
17,28
(index)
00,01
(start-stop)
1
(read)
06
(no range, or all)
22
(assign class)
07,08
(limited qty)
17,28
(index)
00,01
(start-stop)
1
(read)
06
(no range, or all)
22
(assign class)
07,08
(limited qty)
17,28
(index)
06
(no range, or all)
(read)
07,08
(limited qty)
06
(no range, or all)
1
(read)
07,08
(limited qty)
06
(no range, or all)
1
(read)
07,08
(limited qty)
06
(no range, or all)
1
(read)
07,08
(limited qty)
06
(no range, or all)
1
(read)
07,08
(limited qty)
00,01
(start-stop)
06
(no range, or all)
1
(read)
07,08
(limited qty)
17,28
(index)
00,01
(start-stop)
06
(no range, or all)
1
(read)
07,08
(limited qty)
17,28
(index)
APPENDIX C
RESPONSE
(hex)
00, 01
(start-
stop)
129
(response)
17,28
(index)
See Note 2
00, 01
(start-
stop)
129
(response)
17,28
(index)
See Note 2
00, 01
(start-
stop)
129
(response)
17,28
(index)
See Note 2
00, 01
(start-
stop)
129
(response)
17,28
(index)
See Note 2
129
(response)
17, 28
(index)
130
(unsol.resp)
129
(response)
17, 28
(index)
130
(unsol.resp)
129
(response)
130
17,28
(index)
(unsol.resp)
129
(response)
130
17,28
(index)
(unsol.resp)
00,01
(start-
stop)
129
(response)
17,28
(index)
See Note 2