WIRING PRECAUTIONS
Migrating plasticizer is used for vinyl tape. Keep the MR-J3BUS
optical characteristic may be affected.
Generally, soft polyvinyl chloride (PVC), polyethylene resin (PE) and fluorine resin contain non-migrating plasticizer and they do not
affect the optical characteristic of SSCNET III cable. However, some wire sheaths and cable ties, which contain migrating plasticizer
(phthalate ester), may affect MR-J3BUS
In addition, MR-J3BUS
Exposing the SSCNET III cable to solvent/oil may deteriorate the optical fiber and alter its mechanical characteristics. When using the
SSCNET III cable near solvent/oil, take protective measures to shield the SSCNET III cable.
When storing the SSCNET III cable, attach the protective cap to the 20SSC-H connector port for dust protection.
Do not remove the protective cap from the 20SSC-H connector port until just before connecting the SSCNET III cable. Attach the
protective cap to the 20SSC-H connector port after removing the SSCNET III cable to protect the internal optical device from
exposure to dust.
Keep the protective cap and protective tubing clean, and always store them in the provided plastic bag when removing them from the
hardware devices.
When replacing the 20SSC-H, or when sending the product to a local distributor for repair, make sure to attach the protective cap to
the 20SSC-H connector port. Failure to do so may damage the internal optical device and require optical device replacement.
5.1

Cable to Be Used, Applicable Connector and Wire Size

5.1.1

SSCNET III cable

The SSCNET III cable for connecting 20SSC-H with the servo amplifier is described.
Model
*1
MR-J3BUS
M
*1
MR-J3BUS
M-A
*1
MR-J3BUS
M-B
*1.
indicates the cable length.
015 : 0.15m, 03 : 0.3m, 05 : 0.5m, 1 : 1m, 3 : 3m, 5 : 5m, 10 : 10m, 20 : 20m, 30 : 30m, 40 : 40m,
50 : 50m
5.1.2

Power supply cable

The cable for connecting the 20SSC-H power supply connector with the power supply is described.
Model name
FX
-100MPCB
2NC
Preparing the power cable by yourself
To prepare the power cable by yourself, use the following wiring material and connector.
Wire size
Crimp terminal
Housing
M and MR-J3BUS
M-B cable is not affected by plasticizer.
Cable length
0.15, 0.3, 0.5, 1, 3m
5, 10, 20m
30, 40, 50m
Length
Remarks
1m
Accessory of 20SSC-H
For main unit (FX
), 20SSC-H
3UC
For input extension block (FX
2NC
5.1 Cable to Be Used, Applicable Connector and Wire Size
M, and MR-J3BUS
M-A cables.
Operating temperature
Flex Lif
range
Standard
-40 to 85 °C
(-40 to 185 °F)
Standard
-20 to 70 °C
Long flex
(-4 to 158 °F)
Specifications/model name
2
AWG 24(0.2mm
)
1602-0063 (Manufactured by Molex Incorporated)
51030-0330 (Manufactured by Molex Incorporated)
) 51030-0230 (Manufactured by Molex Incorporated)
M-A cables away from vinyl tape because the
Application and remarks
For standard in-panel code
For standard external cable
For long distance cable