From the previous page
Saving positioning parameters and servo parameters (X-axis and Y-axis) to the flash memory
M351
M353
T50
78
M352
7 Before Starting Positioning Operation
From the previous page
FNC 12
K5220
U1\G522
MOV
FNC 12
H007F
U1\G523
MOV
SET
M353
T50
FNC 12
U1\G519
D254
MOV
RST
D254.B
FNC 12
D254
U1\G519
MOV
FNC 12
U1\G619
D255
MOV
RST
D255.B
FNC 12
D255
U1\G619
MOV
FNC 40
M350
M353
ZRST
FNC 40
D250
D255
ZRST
END
7.1 Note on Setting Parameters
Enables control
commands in unit No. 1.
Sets to ON the command to
save each parameter and
table information to the flash
memory in unit No. 1.
Indicates that saving to the
flash memory in unit No. 1
is completed.
When T50 turns ON, saving
K70
of parameters and table
information to the flash
memory in unit No. 1 is
completed.
It takes 7 s or more for
saving.
Reads the operation
command 2 (X-axis) in
unit No. 1.
Resets the servo parameter
update stop command
(X-axis) in unit No. 1.
Sets (writes) the operation
command 2 (X-axis) in unit
No. 1.
Reads the operation
command 2 (Y-axis) in unit
No. 1.
Resets the servo parameter
update stop command
(Y-axis) in unit No. 1.
Sets (writes) the operation
command 2 (Y-axis) in unit
No. 1.

Advertisement