Download Print this page
Mitsubishi FX3U-2HSY-ADP Installation Manual
Mitsubishi FX3U-2HSY-ADP Installation Manual

Mitsubishi FX3U-2HSY-ADP Installation Manual

Hide thumbs Also See for FX3U-2HSY-ADP:

Advertisement

Quick Links

JY997D16401B
Side
B
Side
Side
A
B
JAPANESE
ENGLISH
FX
-2HSY-ADP
3U
INSTALLATION MANUAL
Manual Number
JY997D16401
Revision
B
Date
December 2005
This manual describes the part names, dimensions, mounting, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are
the registered trademarks or trademarks of each company.
Effective Dec. 2005
Specifications are subject to change without notice.
2005 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classify the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by
linked to serious results.
In any case, it is important to follow the directions for usage.
Associated Manuals
Manual name
Manual No.
Description
Expl ains FX
Ser ies PLC
3U
FX
3U
Series
JY997D16501
specification details for I/O,
User's Manual
MODEL CODE:
w i r i n g , i n s t a l l a t i o n , a n d
- Hardware Edition
09R516
maintenance.
FX
/FX
Series
3U
3UC
JY997D16601
Describes PLC programming
Programming Manual
MODEL CODE:
for basic/applied instructions
- B a s i c & A p p l i e d
and devices.
09R517
Instruction Edition
FX
/FX
Series
3U
3UC
JY997D16801
Describes positioning control
User's Manual
MODEL CODE:
and programming using FX
- Positioning Control
09R620
FX
3UC
Series PLC
Edition
How to obtain manuals
For the necessary product manuals or documents, consult with the Mitsubishi
Electric dealer from where you purchase your product.
Applicable Standard
FX
-2HSY-ADP complies with EC directive (EMC Directive) and UL standards
3U
(UL, cUL). Further information can be found in the following manual.
→ → → → Refer to FX
Series Hardware Manual (Manual No. JY997D18801)
3U
1. Outline
The FX
3U
-2HSY-ADP high-speed output special adapter (hereinafter called high-speed
output special adapter) is a special adapter dedicated to FX
pulse signals of a differential line driver system for applicable Servo Amplifiers (or Drive
Unit) of an AC servomotor or stepper motor.
Up to two units of this special adapter can be connected to the main unit per system.
→ → → → For system configuration, refer to the FX
User's Manual - Hardware Edition.
1.1 Incorporated Items
Check if the following product and items are included in the package:
Products
Manual
FX -2HSY-ADP
3U
POWER
Y0/2
Y1/3
Y4/6 Y5/7
This
FP RP
manual
PLS DIR
1.2 Output Number and Signal
When power is turned on, the output numbers and signals of the high-speed output
special adapters are allocated as shown in the table below in the order of it near the
main unit.
Second unit
High-
High-
Analog
Analog
Analog
speed
speed
special
special
special
input
output
function
function
function
special
special
adapter
adapter
adapter
adapter
adapter
*1 A function extension board is required to use the high-speed I/O special adapter
together with a communication/analog special adapter.
→ → → → For system configuration, refer to the FX
User's Manual - Hardware Edition.
Status of
output form
Signal name
First unit
setting
switch
1st axis
may also be
Forward pulse train (FP)
Y000
FP•RP side
Reverse pulse train (RP)
Y004
SG
SG1
Pulse train
Y000
PLS•DIR side
Direction
Y004
SG
SG1
Caution
1) When a high-speed output adapter is connected, the same output number is
allocated to both the main unit and this adapter. Use either output terminal and do
not wire to the unused output terminal.
The outputs from the high-speed output special adapter and main unit are
operated as below:
Output operation
/
3U
High-speed
instructions
output special
Transistor-
adapter
output type
PLSY,PLSR,DSZR,
*1
DVIT,TBL,ZRN,
Operated
Operated
PLSV,DRVI,DRVA
PWM
Operated
Operated
Other
Operated
Operated
*1 The output frequency of transistor outputs in the main unit is a maximum of
100kHz. If the load is operated using pulses at a frequency more than 100kHz,
PLC may be damaged.
*2 PWM instruction has not supported the relay output for the reasons of the
response delay of the output, chattering of contact, the contact life, etc.
2) During STOP or PLC power off modes, set the output form operation.
Do not set the output form operation during pulse train output.
3U
Series PLC. It outputs
1.3 External Dimensions, Part Names, and Terminal Layout
[4]
3U
Series
[3]
[2]
[1]
7 (0.28")
74 (2.92")
Special adapter
First unit
connector cover [2]
or [5] is removed
High-
High-
speed
speed
Main unit
output
input
special
special
adapter
adapter
Terminal layout of [6]
*1
Expansion board
Output number
Name
First
Second
unit
unit
Series
3U
Y0/2+
Y000+
Y002+
Y0/2-
Y000-
Y002-
Output number
Y4/6+
Y004+
Y006+
Y4/6-
Y004-
Y006-
Second unit
SGA
SGA
SGA
2nd axis
1st axis
2nd axis
Y1/3+
Y001+
Y003+
Y001
Y002
Y003
Y1/3-
Y001-
Y003-
Y5/7+
Y005+
Y007+
Y005
Y006
Y007
Y5/7-
Y005-
Y007-
SG2
SG3
SG4
SGB
SGB
SGB
Y001
Y002
Y003
Y005
Y006
Y007
[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] High-speed I/O special adapter connector cover:
SG2
SG3
SG4
Remove this cover for connecting high-speed I/O special adapter on the left side.
[3] Name plate
[4] Special adapter slide lock:
Used to connect special adapter on left side of this special adapter.
[5] Special adapter connector cover:
Remove this cover for connecting special adapter on the left side.
[6] Output terminal block (European type):
Connected to Servo Amplifier (or Drive Unit) to which pulse signal of differential
line driver system can be input.
[7] Output form setting switch
Main unit
Either "Forward pulse train (FP)/Reverse pulse train (RP)" or "pulse train +
direction" is selected. For setting, refer to the following manual.
Relay-output type
→ Refer to FX
/ FX
3UC
3U
[8] Output LED (red):
While instruction is activated,
Lit when output turns ON (if output turns ON and OFF alternately at high speed,
relevant output is ON. (LED is
LED flickers fast).
also ON.)
[9] POWER LED (green):
Lit while power is properly supplied from main unit.
Do not apply PWM instruction
[10] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
for rel ay- output ty pe mai n
*2
unit.
[11] Special adapter fixing hook
[12] DIN rail mounting hook
Operated
[13] Special adapter connector:
Used to connect communication special adapter or analog special adapter to this
adapter on left side.
[14] High-speed I/O special adapter connector:
Used to connect high-speed I/O special adapter to this adapter on left side.
2. Installation
The product can be mounted on DIN rail (DIN46277) or mounted directly using
screws.
For installation/uninstallation and safety precautions, refer to the following manual,
2-φ4.5
too:
[5]
[6]
Mounting holes
[11]
[10]
INSTALLATION
FX -2HSY-ADP
[9]
3U
PRECAUTIONS
[8]
POWER
Y0/2
Y1/3
• Cut off all phases of the power source externally before starting the
Y4/6 Y5/7
[7]
installation or wiring work, thus avoiding electric shock or damages to the
FP RP
product.
PLS DIR
INSTALLATION
PRECAUTIONS
• Use the product in the environment within the general specifications
described in PLC main unit manual (Hardware Edition).
[12]
Never use the product in areas with dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
[10]
vibrations or impacts, or expose it to high temperature, condensation, or wind
15.1 (0.60")
and rain.
If the product is used in such a place described above, electrical shock, fire,
15.5 (0.62")
17.6 (0.70")
malfunction, damage, or deterioration may be caused.
• When drilling screw holes or wiring, cutting chips or wire chips should not
Output LED [8]
enter ventilation slits.
Such an accident may cause fire, failure or malfunction.
Output number
• Do not touch the conductive parts of the product directly, thus avoiding failure
Name
[13]
First
Second
or malfunction.
unit
unit
• Fix the special adapter securely to the specified connector.
Y0/2
Y000
Y002
Incorrect connection may cause malfunction.
Y1/3
Y001
Y003
Y4/6
Y004
Y006
2.1 Connection to the FX
[14]
Y5/7
Y005
Y007
• Refer to the procedure 2) for configuring a new system.
• Refer to the procedure 1) for adding product to an existing system.
Procedure
1) Turn off the power.
Disconnect all the cables connected to the PLC main unit and special adapter.
Dismount the main unit and special adapter mounted on DIN rail or mounted
[7] Output mode setting switch
directly using screws.
Name
Setting
2) Install an expansion board to the main unit.
Fwd pulse train (FP)
For installation of expansion board, refer to the following manual:
Upper
FP RP side
Rev pulse train (RP)
3) Remove the high-speed I/O special adapter
Lower
PLS DIR
Pulse train + direction
connector cover (Right fig. A) and the special
adapter connector cover (Right fig. B) on the
main unit.
Unit
: mm (inches)
In case of connecting this product to a high-
Weight: 80 g (0.18 lbs)
speed I/O special adapter as an addition,
please replace the 'main unit' in the above
description with a 'special adapter' and
perform the procedure as indicated. (Please
replace the following procedures similarly.)
4) Slide the special adapter slide lock (Right
fig.C) of the main unit.
5) Connect the high-
speed I/O special
adapter (Right
fig.D) to the main
unit as shown on
the right.
6) Slide back the
Series User's Manual - Positioning Control Edition.
special adapter
slide lock (Right
fig.C) of the main
unit to fix the high-
speed I/O special
adapter (Right
fig.C).
Connection precautions
• Install the expansion board to be used before connecting a special adapter.
• Install an expansion board when using a special adapter other than a high-
• Connect all the high-speed I/O special adapters before connecting other
→ → → → Refer to the FX
3U
Series User's Manual - Hardware Edition.
, H
S, NH
, SO
, or NO
), flammable gas,
2
2
3
2
2
Series PLC
3U
→ → → → Refer to the FX
3U
Series User's Manual - Hardware Edition
4)
C
3)
4)
4) 4)
B
A
C
C
D
6)
5)
6)
6) 6)
5)
5)
C
speed I/O special adapter in combination with a high-speed I/O special
adapter.
special adapters when they are used in combination.
Do not connect a high-speed I/O special adapter on the left side of a
communication or analog special adapter.

Advertisement

loading
Need help?

Need help?

Do you have a question about the FX3U-2HSY-ADP and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi FX3U-2HSY-ADP

  • Page 1 How to obtain manuals slide lock (Right 6) 6) [8] Output LED (red): For the necessary product manuals or documents, consult with the Mitsubishi PLSY,PLSR,DSZR, While instruction is activated, fig.C) of the main Lit when output turns ON (if output turns ON and OFF alternately at high speed, Electric dealer from where you purchase your product.
  • Page 2 Differential line driver (Equivalent to AM26C31) Warranty Mitsubishi will not be held liable for damage caused by factors found not to be When using a stick terminal with insulating sleeve, choose a wire with proper Forward pulse train, reverse pulse train, or pulse train + the cause of Mitsubishi;...
  • Page 3 Differential line driver (Equivalent to AM26C31) Warranty Mitsubishi will not be held liable for damage caused by factors found not to be When using a stick terminal with insulating sleeve, choose a wire with proper Forward pulse train, reverse pulse train, or pulse train + Output form the cause of Mitsubishi;...