FX
-20SSC-H Positioning Block User's Manual
3U
Current address (pulse)
Zero return complete
Positioning completion
Zero phase passed
Function selection C-4
Note
• The zero return command is not accepted if the zero-point pass signal servo status is OFF.
Before executing zero return, be sure to rotate the servomotor at least once to turn the zero-point pass
signal ON. The zero-point pass signal turns ON when the motor passes the motor reference position signal
(Z-phase).
To execute zero return immediately after power-on, specify "1: Motor Z-phase pass unnecessary after
power-on" (default setting) at servo parameter function selection C-4. With this setting, the zero-point pass
signal turns ON even if the motor does not pass the zero-point (Z-phase).
• With the simultaneous start flag ON, the X-axis mechanical zero return command simultaneously starts the
X and Y-axes mechanical zero return operation.
(The 20SSC-H ignores the Y-axis mechanical zero return command.)
142
BFM #3,#2
Status information
BFM #28 b3
Status information
BFM #28 b6
Servo status
BFM #63 b0
Servo parameters
BFM #15080
(Advanced setting)
8.1 Mechanical Zero Return Control
BFM Number
X-axis
Y-axis
BFM #103,#102
BFM #128 b3
BFM #128 b6
BFM #163 b0
BFM #15280
8 Manual Control
Data type
Monitor data
Monitor data
Monitor data
Monitor data
Servo parameters