Pin Configuration; Input Connector; Power Supply Connector - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
3.5

Pin Configuration

3.5.1

Input connector

Connector pin array (aperture side)
X-INT0
NC
X-INT1
X- A+
X- A-
X- B+
X- B-
X-DOG
S/S
X-START
Caution
The pin array is seen from the connection side (aperture side) of the input connectors of the 20SSC-H.
The pin numbers and the position of
Perform proper wiring while paying attention to the position of notches and the direction of connectors.
Otherwise, the product may be damaged due to wiring mistakes.
3.5.2

Power supply connector

3 Grounding (Green)
2
1
Terminal
name
X-INT0
Interrupt input (for X axis)
NC
Not used
Y-INT0
X-INT1
Interrupt input (for X axis)
NC
Input terminal for A-phase input
X- φ A+
of the manual pulse generator
Y-INT1
(2-phase pulse) (for X axis)
Y- A+
Common terminal for A-phase
Y- A-
i n p u t o f t h e m a n u a l p u l s e
X- φ A-
generator (2-phase pulse)
Y- B+
(for X axis)
Y- B-
Input terminal for B-phase input
X- φ B+
Y-DOG
of the manual pulse generator
(2-phase pulse) (for X axis)
S/S
Common terminal for B-phase
Y-START
i n p u t o f t h e m a n u a l p u l s e
X- φ B-
generator (2-phase pulse)
(for X axis)
Near-point DOG input terminal
X-DOG
(for X axis)
Power input terminal (START,
DOG, INT0 and INT1) 24VDC
S/S
Pins that have the same name
(S/S) are shorted inside.
X-START START input terminal (for X axis) Y-START
vary depending on the connectors for user cables.
(Black)
+
(Red)
Terminal
Description
name
Y-INT0
NC
Y-INT1
Y- φ A+
Y- φ A-
Y- φ B+
Y- φ B-
Y-DOG
S/S
3 Specifications
3.5 Pin Configuration
Description
Interrupt input (for Y axis)
Not used
Interrupt input (for Y axis)
Input terminal for A-phase input
of the manual pulse generator
(2-phase pulse) (for Y axis)
Common terminal for A-phase
i n p u t o f t h e m a n u a l p u l s e
generator (2-phase pulse)
(for Y axis)
IInput terminal for B-phase input
of the manual pulse generator
(2-phase pulse) (for Y axis)
Common terminal for B-phase
i n p u t o f t h e m a n u a l p u l s e
generator (2-phase pulse)
(for Y axis)
Near-point DOG input terminal
(for Y axis)
Power input terminal (START,
DOG, INT0 and INT1) 24VDC
Pins that have the same name
(S/S) are shorted inside.
START input terminal (for Y axis)
25
1
2
3
4
5
6
7
8
9
10