10.9.2 With Mode - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

10.9.2 With mode

The specified m code turns ON when the operation starts.
1. Operation
Speed
m code No.
m code ON
m code OFF command
1) The 20SSC-H stores "10010" in the m code No. of monitor data while also starting table No. 0 with
"10010" and turning ON the m code ON flag in the status information.
2) At m code OFF, the m code ON flag and m code itself turns OFF, and the 20SSC-H stores "-1" in the m
code No. of monitor data.
3) The next table No. cannot be executed unless the m code OFF command has been activated.
m code OFF command
m code number
Number of the table in operation
m code ON
Note
• With a "10000" in the m code information, the 20SSC-H turns to standby mode. With the start command or
m code OFF command, the m code turns OFF.
• The 20SSC-H continues operating during multi-speed operation and continuous pass operation without m
code OFF commands. The specified m codes also turn ON in consecutive order.
m code No.
m code ON
m code OFF command
2. Available m code Nos.
To use the m code in the with mode, set the m code in the range from 10000 to 32767.
-1
10010
-1
ON
OFF
OFF
ON
OFF
OFF
Table No.
Operation information
0
1
(1-speed positioning)
1
1 (1-speed positioning)
2
0
(END)
→ For the parameters, control data and monitor data, refer to Chapter 11
Operation command 1
BFM #518 b11
BFM #9
BFM #16
Status information
BFM #28 b8
Speed
10010
ON
OFF
OFF
ON
OFF
10011
ON
OFF
ON
m code information
10010 (with mode)
10011
-1
BFM number
X-axis
Y-axis
BFM #618 b11
BFM #109
BFM #116
BFM #128 b8
-1
10011
ON
OFF
The next operation is executed
even if the m code OFF command is not ON.
10 Table Operation
10.9 m code
Time
-1
(with mode)
Data type
Control data
Monitor data
Monitor data
Monitor data
Time
10012
-1
OFF
ON
OFF
201
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Table of Contents