Model Code [Bfm #30]; Status Information 2 [Bfm #32, Bfm #132]; Current Address When An Interrupt Occurs (Int0) [Bfm #35, #34, Bfm #135, #134], Current Address When An Interrupt Occurs (Int1) [Bfm #37, #36, Bfm #137, #136]; Deviation Counter Value [Bfm #51, #50, Bfm #151, #150] - Mitsubishi FX3U-20SSC-H User Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

11.3.19 Model code [BFM #30]

The model code of the 20SSC-H is stored.
BFM Number
X-axis
BFM #30

11.3.20 Status information 2 [BFM #32, BFM #132]

Status of the 20SSC-H can be checked by ON/OFF statuses of each bit.
BFM Number
X-axis
BFM #32
BFM #132
11.3.21 Current address when an interrupt occurs (INT0) [BFM #35, #34, BFM #135, #134],
Current address when an interrupt occurs (INT1) [BFM #37, #36, BFM #137, #136]
The current address when an interrupt input (INT0/INT1) occurs in target positioning operation is stored in
user units. (Ver. 1.30 or later)
BFM Number
X-axis
BFM
BFM #35, #34
#135, #134
BFM
BFM #37, #36
#137, #136
Target positioning operations.
Positioning operation
Interrupt 1-speed constant quantity feed
Interrupt 1-speed constant Quantity feed
(constant position stop mode)
Interrupt 2-speed constant quantity feed
Interrupt stop operation
Linear interpolation operation
(interrupt stop)
Note
The error in the calculation of user units is included in the value of the current address when an interrupt
occurs.

11.3.22 Deviation counter value [BFM #51, #50, BFM #151, #150]

The deviation counter value of the servo amplifier is stored.
BFM Number
X-axis
BFM
BFM #51,#50
#151,#150
232
Y-axis
-
The model code of the 20SSC-H is K5220.
Bit
Number
Y-axis
Positioning parameter change completion flag
(Ver. 1.20 or later)
Turns ON when positioning parameter change is
b0
completed.
Automatically turns OFF when the positioning parameters
enable command turns OFF.
b1 to b15
Not available
Y-axis
Current address when an interrupt input (INT0) occurs (in user units)
Current address when an interrupt input (INT1) occurs (in user units)
Current address when an interrupt occurs
Y-axis
Deviation counter value of the servo amplifier (PLS)
11 Buffer Memory (Parameters & Monitored Data)
Description
Description
Description
Current address when an interrupt occurs
(INT0)
Description
11.3 Monitor Data
Value Format
Default
Decimal
-
Value Format
Default
Bit
H0000
Value Format
Default
Decimal
-
Decimal
-
(INT1)
-
-
-
-
Value Format
Default
Decimal
-

Advertisement