JY997D36701A
FX
-2HC
3U
USER'S MANUAL
Manual Number
JY997D36701
Revision
A
Date
December 2009
This manual describes the part names, dimensions, mounting, wiring, and
specifications of the product. Before use, read this manual and the manuals of
all relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective December 2009
Specifications are subject to change without notice.
©
2009 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
FX
3U
Series
JY997D16501
E xplains the FX
3 U
Series P LC
User's Manual
MODEL CODE:
s p e c i f i c a t i o n s f o r I / O , w i r i n g ,
- Hardware Edition
09R516
installation, and maintenance.
FX
Series
JY997D28701
Explains the FX
Series PLC
3UC
3UC
User's Manual
MODEL CODE:
s p e c i f i c a t i o n s f o r I / O , w i r i n g ,
- Hardware Edition
09R519
installation, and maintenance.
F X
/ F X
/ F X
3 G
3 U
3 U C
Series
JY997D16601
D e s c r i b e s F X
3 G
/ F X
3 U
Programming Manual
MODEL CODE:
Series PLC programming for basic/
applied instructions and devices.
- Basic & Applied
09R517
Instruction Edition
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
Certification of UL, cUL standards
The following product has UL and cUL certification.
UL, cUL File Number:E95239
Models:
MELSEC FX
3U
series manufactured
from December 1st, 2009
FX
3U
-2HC
Industrial automation
Elincom Group
European Union: www.elinco.eu
Russia: www.elinc.ru
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more details please contact the
local Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2004/108/EC) when
used as directed by the appropriate documentation.
Attention
• This product is designed for use in industrial applications.
• Manufactured by:
Mitsubishi Electric Corporation
2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan
• Manufactured at:
Mitsubishi Electric Corporation Himeji Works
840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan
• Authorized Representative in the European Community:
Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
3U
series manufactured
from December 1st, 2009
FX
3U
-2HC
Standard
EN61131-2:2003
Compliance with all relevant aspects of the standard.
Programmable controllers
EMI
- Equipment requirements
• Radiated Emissions
and tests
• Conducted Emissions
EMS
• Radiated electromagnetic field
• Fast Transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Caution for EC Directive
may
• Installation in Enclosure
Programmable logic controllers are open-type devices that must be installed and
used within conductive control cabinets. Please use the programmable logic
controller while installed within a conductive shielded control cabinet. Please secure
the cabinet door to the control cabinet (for conduction). Installation within a control
cabinet greatly affects the safety of the system and aids in shielding noise from the
programmable logic controller.
1. Outline
1.1 Outline
The hardware high-speed counter block is a 2-channel high-speed counter. It is a
special function block for the FX
and FX
series PLC.
3U
3UC
1.2 Major Features of the FX
-2HC
3U
• Differential-Line-Driver (AM26C31 or equivalent) and open collector output
encoders are available for the FX
-2HC.
3U
/ F X
3 U C
• The FX
-2HC has two outputs per channel. When the counter value coincides with
3U
an output compare value, the appropriate output is set ON. The output transistors
are individually isolated to allow either sink or source connection methods.
• Various counter modes, such as 1-phase or 2-phase, 16-bit or 32-bit modes, can be
selected using commands in the sequence program. Allow the FX
run only after setting these mode parameters.
1.3 Incorporated Items
Verify that the following product and items are included in the package:
Included Items
FX
3U
-2HC
Special unit/block No. label
Dust proof protection sheet
Manuals [Japanese version]
Manuals [English version] (This manual)
1.4 External Dimensions, Part Names, and Terminal Layout
[1]
[9]
[8]
9(0.36")
87(3.43")
Weigh: 0.2kg (0.44lbs)
No.
Direct mounting hole: 2 holes of
[1]
Used when attaching FX
3U
Extension cable (PLC side)
[2]
Used to connect this special function block to the FX
extension block.
[3]
CH1 connector
[4]
CH2 connector
Remark
Status LED (the upper side: CH1, the lower side: CH2)
POWER
Power LED
(Green)
UP (Red)
Up count LED
DOWN (Red)
Down count LED
A phase input LED
A (Red)
[5]
B (Red)
B phase input LED
DIS (Red)
DISABLE input LED T h e r e s p e c t i v e L E D i s O N / O F F
PRE (Red)
PRESET input LED
YH1 (Red)
YH1 output LED
YH2 (Red)
YH2 output LED
[6]
Top cover
Extension connector (Extension side)
[7]
Used to connect a FX
3U
block. Remove top cover for connecting.
[8]
DIN rail mounting hook
[9]
DIN rail mounting groove (DIN rail: DIN46277, 35mm (1.38") width)
FX
-2HC connector arrangement
3U
CH1
A24+
A12+
Phase A
A5+
A-
input
B24+
B12+
Phase B
input
B5+
B-
-2HC unit to
3U
PRESET
P24+
P12+
input
P5+
P-
DISABLE
XD24
XD5
input
COMD
1 Unit
1 Sheet
YH1 output
YH1+
YH1-
1 Sheet
YH2 output
YH2+
YH2-
1 manual
1 manual
2. Installation, Connect to the PLC
Without top cover
[2]
[3] [4]
INSTALLATION
2-Ø4.5 mounting holes
PRECAUTIONS
[5]
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
[5]
INSTALLATION
[6]
PRECAUTIONS
[5]
• Use the product within the generic environment specifications described in PLC
main unit manual.
4(0.16")
Never use the product in areas with excessive dust, oily smoke, conductive
[7]
55(2.17")
dusts, corrosive gas (salt air, Cl
or impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
Name
deterioration or damage may occur.
• Do not touch the conductive parts of the product directly.
4.5 (0.18") (mounting screw: M4 screw)
Doing so may cause device failures or malfunctions.
-2HC directly.
• Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC board,
thereby causing nonconformities.
3U
/FX
3UC
main unit or an
• When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.
• Be sure to remove the dust proof sheet from the PLC's ventilation port when
installation work is completed.
Failure to do so may cause fire, equipment failures or malfunctions.
• Connect extension cables securely to their designated connectors.
ON when the 5V power supply is
normally supplied from the PLC.
Loose connections may cause malfunctions.
The respective LED is ON according
2.1 Mounting
to up/down count direction of the
The product is mounted by the following method.
counter.
• DIN rail mounting
The respective LED is ON (flicker)
• Direct mounting (mounting screw: M4 screw)
according to ON/OFF of
A and
B
For further information on installation arrangements, refer to the following manuals.
input.
according to ON/OFF of PRESET and
2.1.1
DIN Rail Mounting
DISABLE input.
The product can be mounted on a DIN rail
(DIN46277, 35mm (1.38") width).
T h e r e s p e c t i v e L E D i s O N / O F F
1) Fit the upper edge of the DIN rail mounting
according to status of YH1 and YH2
groove (fig. A) onto the DIN rail.
output.
2) Press the product against the DIN rail.
- An interval space of 1 to 2 mm (0.04" to
0.08") between each unit is necessary.
extension block to the right of this special function
2.1.2
Direct Mounting (mounting screw: M4 screw)
The product can be installed directly with screws.
Refer to the External Dimensions (section 1.4) for the product's mounting hole
pitch information.
CH2
An interval space between each unit of 1 to 2 mm (0.04" to 0.08") is necessary.
A24+
A12+
2.2 Connection to the PLC
A5+
A-
A maximum of eight
side of the powered extension unit/block. A unit number of No.0 to No.7 is
B24+
B12+
assigned based on the order in which special function units/blocks are attached to
B5+
B-
the main unit.
For connection to an FX
P24+
P12+
FX
-CNV-IF or FX
2NC
P5+
P-
*1 Up to seven special function units/blocks in total can be connected to the
FX
3UC
Notch
Notch
blocks begins with No.1.
For further information on installation arrangements, refer to the following manuals.
XD24
XD5
COMD
3. Wiring (Power supply and analog input)
YH1+
YH1-
WIRING
YH2+
YH2-
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
, H
S, SO
, or NO
), flammable gas, vibration
2
2
2
2
→ Refer to the FX
Series User's Manual - Hardware Edition.
3U
→ Refer to the FX
3UC
Series User's Manual - Hardware Edition.
1)
A
2)
*1
FX
-2HC(s) are connectable with the main unit or the right
3U
Series PLC or FX
Series PLC extension block, an
3UC
2NC
-1PS-5V is required.
3UC
-32MT-LT(-2) PLC. Unit numbers assigned to special function units/
→ Refer to the FX
Series User's Manual - Hardware Edition.
3U
→ Refer to the FX
3UC
Series User's Manual - Hardware Edition.
Need help?
Do you have a question about the MELSEC-F FX3U-2HC and is the answer not in the manual?
Questions and answers