2) When the STOP command or rotation limit switch turns ON during deceleration stop, the servo motor
suddenly stops in accordance with the sudden stop deceleration time (sudden stop interpolation time
constant).
In individual axis operation
Speed
Maximum speed
Operation speed
STOP command
STOP command
Forward rotation
limit (LSF)
Reverse rotation
limit (LSR)
FLS terminal input Servo terminal information
RLS terminal input Servo terminal information
Maximum speed
Operation speed
Acceleration/
deceleration time
change command
(Ver. 1.30 or later)
Deceleration time
Deceleration time 2 (Ver. 1.30 or later)
Sudden stop deceleration time
90
Real sudden stop deceleration time
Real deceleration time
OFF
Operation command 1
Operation command 1
Operation command 1
Operation speed 1
Operation speed 2
JOG speed
Zero return speed (high speed)
Zero return speed (creep)
Operation command 2
7 Before Starting Positioning Operation
7.5 Sudden stop selection (Ver.1.20 or later)
ON
BFM Number
X-axis
BFM #518 b1
BFM #618 b1
BFM #518 b2
BFM #618 b2
BFM #518 b3
BFM #618 b3
BFM #8 b0
BFM #108 b0
BFM #8 b1
BFM #108 b1
BFM #14009,#14008
BFM #14209,#14208
BFM #503,#502
BFM #603,#602
BFM #507,#506
BFM #607,#606
BFM #14013,#14012
BFM #14213,#14212
BFM #14025,#14024
BFM #14225,#14224
BFM #14027,#14026
BFM #14227,#14226
BFM #519 b5
BFM #619 b5
BFM #14020
BFM #14220
BFM #14110
BFM #14310
BFM #14102
BFM #14302
Time
Sudden stop
deceleration time
Deceleration time
Data type
Y-axis
Control data
Control data
Control data
Monitor data
Monitor data
Positioning parameters
Control data
Control data
Positioning parameters
Positioning parameters
Positioning parameters
Control data
Positioning parameters
Positioning parameters
Positioning parameters