Configuration Example For Efd - Cisco ASR 920 Series Configuration Manual Ethernet Router

Hide thumbs Also See for ASR 920 Series:
Table of Contents

Advertisement

Configuration Example for EFD

Command or Action
Step 5
ethernet cfm domaindomain-name level level-id [direction
outward]
Example:
Device(config)# ethernet cfm domain G8032 level 4
Step 6
service {ma-name | ma-num | vlan-id vlan-id | vpn-id
vpn-id} [port | vlan vlan-id [direction down]]
Example:
Device(config-ecfm)# service 8032_service evc
8032-evc vlan 1001 direction down
Step 7
continuity-check [interval time | loss-threshold threshold
| static rmep]
Example:
Device(config-ecfm-srv)# continuity-check interval
3.3ms
Step 8
efd notify g8032
Example:
Device(config-ecfm-srv)# efd notify g8032
Step 9
efd line-protocol
Example:
Device(config-ecfm-srv)# efd line-protocol
Step 10
end
Example:
Device(config-ecfm-srv)# end
Configuration Example for EFD
The following example shows a sample output of a service instance that is brought down by an EFD action.
Device#show ethernet ser ins int g0/0/6
Identifier Type Interface State CE-Vlans
2 Static GigabitEthernet0/0/6 ErrorDis
Carrier Ethernet Configuration Guide (Cisco ASR 920 Series)
62
Using Ethernet Fault Detection
Purpose
Configures the CFM domain for ODU 1 and enters
Ethernet CFM configuration mode.
Defines a maintenance association for ODU 1 and
enters Ethernet CFM service instance configuration
mode.
Enables the transmission of continuity check messages
(CCMs).
Enables CFM to notify registered protocols when a
defect is detected or cleared, which matches the current
fault alarm priority.
Triggers line-protocol action when the CFM
error-database is updated.
Returns to user EXEC mode.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents