Configuring Ethernet CFM
Command or Action
Step 19
snmp-server enable traps ethernet cfm cc [mep-up]
[mep-down] [config] [loop] [cross-connect]
Example:
Device(config)# snmp-server enable traps ethernet
cfm cc mep-up mep-down config loop cross-connect
Step 20
snmp-server enable traps ethernet cfm crosscheck
[mep-unknown | mep-missing | service-up]
Example:
Device(config)# snmp-server enable traps ethernet
cfm crosscheck mep-unknown mep-missing service-up
Step 21
end
Example:
Device(config)# end

Provisioning the Network on the CE-B

SUMMARY STEPS
1. enable
2. configure terminal
3. ethernet cfm domain domain-name level level-id
4. service short-ma-name evc evc-name vlan vlanid direction down
5. continuity-check
6. continuity-check [interval cc-interval]
7. exit
8. mep archive-hold-time minutes
9. exit
10. ethernet cfm global
11. ethernet cfm traceroute cache
12. ethernet cfm traceroute cache size entries
13. ethernet cfm traceroute cache hold-time minutes
14. snmp-server enable traps ethernet cfm cc [mep-up] [mep-down] [config] [loop] [cross-connect]
15. snmp-server enable traps ethernet cfm crosscheck [mep-unknown | mep-missing | service-up]
16. end
Carrier Ethernet Configuration Guide (Cisco ASR 920 Series)
150
Configuring Ethernet Connectivity Fault Management in a Service Provider Network
Purpose
Enables SNMP trap generation for Ethernet CFM
mep-up, mep-down, config, loop, and cross-connect
events.
Enables SNMP trap generation for Ethernet CFM
mep-unknown, mep-missing, and service-up continuity
check events in relation to the cross-check operation
between statically configured MEPs and those learned
via CCMs.
Returns to privileged EXEC mode.