Configuring Ethernet Connectivity Fault Management in a Service Provider Network
Configuring Ethernet CFM
Configuring Ethernet CFM consists of the following tasks:
Provisioning the Network
Provisioning the Network on the CE-A
SUMMARY STEPS
1. enable
2. configure terminal
3. ethernet cfm domain domain-name level level-id
4. service short-ma-name evc evc-name vlan vlanid direction down
5. continuity-check
6. continuity-check [interval cc-interval]
7. exit
8. mep archive-hold-time minutes
9. exit
10. ethernet cfm global
11. ethernet cfm traceroute cache
12. ethernet cfm traceroute cache size entries
13. ethernet cfm traceroute cache hold-time minutes
14. snmp-server enable traps ethernet cfm cc [mep-up] [mep-down] [config] [loop] [cross-connect]
15. snmp-server enable traps ethernet cfm crosscheck [mep-unknown | mep-missing | service-up]
16. end
DETAILED STEPS
Command or Action
Step 1
enable
Example:
Device> enable
Step 2
configure terminal
Example:
Device# configure terminal
Purpose
Enables privileged EXEC mode.
• Enter your password if prompted.
Enters global configuration mode.
Carrier Ethernet Configuration Guide (Cisco ASR 920 Series)
Configuring Ethernet CFM
137
Need help?
Do you have a question about the ASR 920 Series and is the answer not in the manual?