Stopping And Starting Link Monitoring Operations - Cisco ASR 920 Series Configuration Manual Ethernet Router

Hide thumbs Also See for ASR 920 Series:
Table of Contents

Advertisement

Using Ethernet Operations Administration and Maintenance
DETAILED STEPS
Command or Action
Step 1
enable
Example:
Device> enable
Step 2
configure terminal
Example:
Device# configure terminal
Step 3
interface type number
Example:
Device(config)# interface gigabitEthernet 0/0/1
Step 4
ethernet oam link-monitor supported
Example:
Device(config-if)# ethernet oam link-monitor
supported
Step 5
exit
Example:
Device(config-if)# exit

Stopping and Starting Link Monitoring Operations

Link monitoring operations start automatically when Ethernet OAM is enabled on an interface. When link
monitoring operations are stopped, the interface does not actively send or receive event notification OAM
PDUs. The tasks in this section describe how to stop and start link monitoring operations.
Stopping Link Monitoring Operations
Perform this task to stop link monitoring operations.
Stopping and Starting Link Monitoring Operations
Purpose
Enables privileged EXEC mode.
• Enter your password if prompted.
Enters global configuration mode.
Specifies an interface and enters interface
configuration mode.
Enables link monitoring on the interface.
Returns to global configuration mode.
Carrier Ethernet Configuration Guide (Cisco ASR 920 Series)