Download Project To Target System - Siemens SIMOTION D410-2DP/PN Installation Manual

Table of Contents

Advertisement

5. Click "Firmware update" to download the new firmware to the devices. To do so, you must
select all components whose firmware is to be updated.
6. When the firmware update is complete, switch the 24 V power supply off and back on again.
The device is now ready for operation.
Note
The SINAMICS components must be configured for a firmware update to take place. The
firmware cannot be updated if the components have not been configured.
You can also update the firmware using the expert list. See the
Commissioning Manual for a description of how to do this.
8.4.5.4

Download project to target system

Once all the changes required for upgrading your project have been made, you must download
the project to the SIMOTION D410-2.
Requirement
The firmware required is located on the CompactFlash card; for information, refer to the section
titled Firmware update using a CompactFlash Card (Page 287).
You have recompiled the project and checked it for consistency. See Section Save project,
compile and check consistency (Page 280).
Procedure
1. Save and compile the project.
2. Click "Connect to selected target systems" to establish a connection to the target system.
3. Execute "Download project to target system" and then "Copy RAM to ROM" to download
the upgraded project to the CompactFlash card as well.
4. Because of the automatic follow-up configuration in the SINAMICS Integrated drive, you
must now execute "Load CPU / drive unit to PG".
5. Save the project.
SIMOTION D410-2
Commissioning and Hardware Installation Manual, 01/2015
Service and maintenance
8.4 Performing a firmware and project update
SINAMICS S120
289

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410-2 dp

Table of Contents