5 Installation and commissioning
5.2

IP addresses and device names

The following IP addresses and device names are used in the application example.
Subsequent changes can be made at any time.
Table 5-1: IP addresses and device names
Components
SIMATIC S7-1200
SINAMICS G120
SIMATIC KTP400
PG/PC
The network mask is always 255.255.255.0 and no router is used.
5.3

Download the project to the components

The steps listed in the following table show how to load the individual programs of
the application example into the components. The SIMATIC HMI is optional.
Table 5-2: Download the project to the components
No.
Action
1.
Retrieve the project contained
in the zip file
"109485727_G120_CU240E2
PN_at_S7_1200_SINA_SPEE
D_v10" to a local directory.
2.
Double-click the ap14 file in
the project folder just retrieved
in order to open the project in
TIA Portal.
3.
If TIA Portal opens in the
Portal view, go to the bottom
left to switch to the "Project
view".
Drehzahlachse mit SINA_SPEED
Entry-ID: 109485727,
V1.0,
SIMATIC_CPU1215C
SINAMICS_CU240E
SIMATIC_KTP400
06/2017
Device name
192.168.0.1
192.168.0.2
192.168.0.10
-
192.168.0.200
Remark
-
-
IP address