Diagnostics

9.3 Additional service and diagnostics options

9.3
Additional service and diagnostics options
9.3.1

SIMOTION Task Profiler application

The SIMOTION Task Profiler is a dedicated application installed parallel to SIMOTION SCOUT
during SIMOTION SCOUT setup. The Task Profiler can be called in online mode using device
diagnostics in SIMOTION SCOUT or the Windows application. In the event of a malfunction
or error, the Task Trace data can be written to a directory or the CompactFlash card. It can
then be processed using the Task Trace Viewer.
Additional references
For detailed information, refer to the
9.3.2

Diagnostics via the SIMOTION IT web server

SIMOTION D410-2 has an integrated web server. Use is not subject to a license.
In addition to customized web pages and the option of performing firmware and project
updates, SIMOTION IT web server provides comprehensive device and diagnostic information
that can be called using a standard PC with a web browser.
Security concept of HTTP/S, FTP, and Telnet access on the web server
With version V4.4 and higher, access to the SIMOTION IT web server is protected by a multi-
level security concept.
The security status of the web server is indicated by the security level on the web page. This
security level can have three different stages: Low, normal, high.
Security Level Low
The device is supplied with an empty user database. No projects exist yet. The security level
is low to allow configuration of the device.
● In this state, access to the web server as an anonymous user is possible to enable use of
functions such as the project and firmware update or OPC XML.
● Access to the FTP and Telnet is also possible.
● New users can be entered in the empty user database.
In this state, series commissioning is possible via the web server.
NOTICE
Protecting the device
Security level low should only be used for commissioning and service as otherwise the device
is not adequately access protected.