7.11

Configuring technology objects and I/O variables

7.11.1

Configuring global measuring inputs

Overview
The type of measuring input must be selected during the configuration of the TO measuring
input, see following table.
Table 7-8
Measuring input types
Measuring input types
Standard
(global measuring in‐
put)
Drive-related (local
measuring input)
Listening measuring in‐
put
A detailed comparison of "local" and "global" measuring inputs as well as an overview of which
modules support local or global measuring inputs can be found in Appendix Configuring drive-
related I/Os (without symbolic assignment) (Page 317).
Procedure
If a global measuring input is selected, it must be assigned a hardware input.
Click the "Assign" button
used) I/O.
Note
Only those I/Os are displayed that have the appropriate measuring input functionality (MI_xx
[channel name, terminal number]). If no suitable I/Os are displayed, you must first configure
the I/Os (I/O must be configured as "measuring input").
SIMOTION D410-2
Commissioning and Hardware Installation Manual, 01/2015
Explanation
Compared with the drive-related local measuring inputs, global measuring inputs have extended
functionality and also support a symbolic configuration.
They are therefore set as standard.
The drive-related local measuring inputs are configured via drive parameters, see Section Config‐
uring drive-related I/Os (without symbolic assignment) (Page 317) in the Appendix.
Through the configuration of a listening measuring input, measuring can be performed simultane‐
ously on several axes or external encoders with one measuring input. Detailed information can be
SIMOTION Motion Control Output Cams and Measuring Inputs Function Manual.
found in the
7.11 Configuring technology objects and I/O variables
to open the Assignment dialog box and select a free (i.e. not yet
Commissioning (software)