Feature Guide References
None
Line Signal Setting—E&M-P Pulse Length—E&M-P Seizure ACK
Enables the PBX to wait for an E & M-P seizure ACK signal.
Value Range
No, Yes
Maintenance Console Location
2.8.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Line Signal Setting—E&M-P Pulse Length—Wink Signal Width
Specifies the length of a wink signal.
Value Range
32 × n (n=4–9) ms
Maintenance Console Location
2.8.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Caller ID—Caller ID Start Code
Selects the DTMF code used to detect the beginning of a Caller ID series.
Value Range
*, #, A–D
Maintenance Console Location
2.8.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
2.8 [1] Configuration
PC Programming Manual
279