2.8 [1] Configuration
Programming Manual References
2.8.1 [1-1] Slot
2.9.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Extension Inter-digit
2.9.17 [2-9] System Options—Option 2—ISDN en Bloc Dial—[#] as End of Dial for en Bloc mode
2.10.4 [3-1-4] Dialling Plan
Feature Guide References
1.21.1.1 Integrated Services Digital Network (ISDN)—SUMMARY
ISDN Centrex
Enables the use of the telephone company's ISDN Centrex Service features.
Value Range
Disable, Enable
Maintenance Console Location
2.8.16 [1-1] Slot—Port Property - PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
1.21.1.1 Integrated Services Digital Network (ISDN)—SUMMARY
Networking Data Transfer
Enables transmission of extension status data to connected PBXs in a network. This setting is only
available when Port Type on this screen has been set to QSIG-Slave or QSIG-Master.
Value Range
No, Yes
Maintenance Console Location
2.8.16 [1-1] Slot—Port Property - PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
2.16 [9] Private Network
Feature Guide References
1.30.5.1 Network Direct Station Selection (NDSS)
Loopback Test started by Network
Enables a loopback test started from the network side, to be performed on the PRI23 card.
Note
The version of the PRI23 card must be 2.000 or later.
200
PC Programming Manual