2.8 [1] Configuration
Feature Guide References
None
Meter Pulse Detection—Mode
Specifies the mode for call charge meter pulses.
Value Range
No Detection: Meter pulses are not sent or received.
Outgoing call only: Sends a call charge meter pulse for outgoing trunk calls.
Both calls: Sends and receives call charge meter pulses.
Maintenance Console Location
2.8.22 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None
Feature Guide References
None
Meter Pulse Detection—Bit Position
Specifies the bit position of a call charge meter pulse.
Value Range
A-bit, B-bit, C-bit, D-bit
Maintenance Console Location
2.8.22 [1-1] Slot—Card Property - E1 type—Line Signal Setting
Programming Manual References
None
Feature Guide References
None
Meter Pulse Detection—Length
Specifies the length that a call charge meter pulse must be for the PBX to recognise it as a call charge
meter pulse.
Value Range
8 × n (n=1–80) ms
Maintenance Console Location
2.8.22 [1-1] Slot—Card Property - E1 type—Line Signal Setting
246
PC Programming Manual