Panasonic KX-TDA100 Pc Programming Manual page 96

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

2.7 Help
Q
The Maintenance Console cannot connect to the PBX via modem.
A
Q
The Maintenance Console cannot connect to the PBX via ISDN Remote.
A
Q
Can I perform initial setup of the PBX without being connected to the PBX?
A
Maintenance Console Software
Q
How do I confirm the software version of the PBX or installed cards?
A
Q
Not all of the characters of a setting can be displayed because the column is
too narrow.
A
Card Status
Q
The status of a new card will not change to "INS".
A
Q
I want to set the status of only 1 port of the IP-GW4 card to "OUS".
A
96
PC Programming Manual
Is the dial number of the modem correct? For more details, see 2.18.1 [11-1] Main.
Has a modem been installed to the PBX?
Are the modem settings of the PBX and Maintenance Console correct? For more details,
see 2.18.1 [11-1] Main.
Is the password correct?
Is the Maintenance Console not connected to the PBX by another connection method?
Are the ISDN Remote settings of the PC correct? For more details, see 2.18.1 [11-1]
Main.
Is the ISDN Remote dial number correct?
Is the password correct?
Is the Maintenance Console not connected to the PBX by another connection method?
Yes. This is possible in Batch mode.
Create a new system data file using 2.2.1 Start Menu—New, edit settings as required,
and then upload this file to the PBX later (see 2.6.2 Utility—File Transfer PC to PBX
(SD Card)).
From 2.8.1 [1-1] Slot, click Summary. Summary information, including software
versions, is displayed for all cards installed in the PBX.
Move the mouse to the line between the names of 2 setting items, at the top of the table.
The pointer will change to a double arrow. Click and drag the line to the right until all
characters are displayed.
With the new card installed, does the total number of extensions or trunks exceed the
maximum supported by the PBX?
Is the type of card installed in the slot different from the card type set as "Pre-install" for
that slot? Confirm that the correct card is installed in the slot.
Is the card firmly and fully installed in the slot? Confirm that the card is installed correctly
in the slot.
Confirm that the card is not damaged.
This cannot be done, since the IP-GW4 card requires both channels of a port to be set
to "OUS"/"INS" together.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda30Kx-tda200Kx-tda600

Table of Contents