How To Install Internal Hard Disk Units - Fujitsu PRIMERGY TX120 User Manual

Hide thumbs Also See for PRIMERGY TX120:
Table of Contents

Advertisement

Before installing optional hard disk units, refer to "B.2 Internal Hard Disk Units" ( pg.202) to check to
see the packaged items.
Slot number
The slot numbers which are displayed on the software such as RAID management tool correspond to the
hard disk bay numbers as follows.
Bay number
Slot number
Replacing the failed internal hard disk unit
When the hard disk is failed, it can be replaced and repaired without turning off the server and peripheral
devices (hot-swappable/hot-pluggable). For details about the array system and replacing the failed hard
disk unit, refer to "Integrated Mirroring SAS User's Guide" in the Array Controller Document & Tool
CD.

7.5.3 How to Install Internal Hard Disk Units

1
Turn off the server and connected devices, and unplug all power cables from
the outlet.
2
Remove the drive cover.
"1.4.1 Opening the Drive Cover" (pg.28)
3
Touch a metal part of the server to discharge static electricity.
4
Remove the dummy unit from the bay to accommodate an internal hard disk
unit.
Pull the dummy unit out towards you with the tabs pressed inward.
Be sure to keep the removed dummy units for later use.
1
2
0
1
Tabs
PRIMERGY TX120 User's Guide
135

Hide quick links:

Advertisement

Table of Contents
loading