Installing Serverview - Fujitsu PRIMERGY TX120 User Manual

Hide thumbs Also See for PRIMERGY TX120:
Table of Contents

Advertisement

Chapter 6 High Reliability Tools
Temperature monitoring
ServerView monitors the temperature. In an environment where ServerView is not in use, the increasing
temperature inside the server, caused by the fan malfunction as described above, can not be detected to
prevent a system failure. The server must restart as those errors are detected by using BIOS Setup Utility
or Server Management Tools.
Voltage monitoring
ServerView monitors the voltage. In an environment where ServerView is not in use, voltage surge
cannot be detected during operation. The server must restart as those errors are detected by using BIOS
Setup Utility or Server Management Tools. Voltage surges may result in malfunction or data loss.
Power supply monitoring
ServerView monitors the power supply. In an environment where ServerView is not in use, power
supply irregularities cannot be detected during operation. The server must restart as those errors are
detected by using BIOS Setup Utility or Server Management Tools. System stops due to power supply
failures cannot be prevented.

6.2.1 Installing ServerView

When installed using ServerStart
When the OS has been installed using ServerStart, ServerView has been also installed together with the
OS as well as other high reliability tools.
When installed manually (Linux)
ServerView cannot be installed using ServerStart. To install ServerView manually on a Linux system,
refer to "Chapter 2 Installation" in "ServerView User's Guide".
Be sure to install SNMP service before installing ServerView.
When an error screen appears after ServerView installation
(Windows Server 2003 only)
If Windows Server 2003 Service Pack 1 is applied, the following message may appear on restarting
immediately after installing/uninstalling ServerView.
In order to protect the computer, this program is terminated by
Windows.
Name: SNMP Service
This message does not imply an error. Click [Close Message] to close the message.