Chapter 9 Operation and Maintenance
System timer error
Real time clock error
Check date and time settings
Previous boot incomplete - Default
configuration used
CPU had been changed - Run SETUP
CPU mismatch detected
Available CPUs do not support the same bus
frequency- System halted!
iRMC Controller Error
176
table: List of POST error messages
Message
Description
It indicates a system clock error. Turn off the server and turn it
back on. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
It indicates a Real Time Clock (RTC) error. Start up BIOS
Setup Utility, and enter the current date and time. If the message
still appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
It indicates an error of the date and time settings. Start up BIOS
Setup Utility, and enter the current date and time. If the message
still appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
BIOS is started up with the default values because POST was
not complete during the last startup, or power-off or reset was
performed three times or more in POST, which was considered
as an error. Check the BIOS settings.
If POST was not complete, check the SEL around this entry to
identify the relevant part and take necessary measure. If you
cannot identify the relevant part, separate PCI cards, CPU,
memory modules, and baseboard in this order.
CPU has been changed.
Check whether a proper CPU is installed. If the message
appears although it is proper, start up BIOS Setup Utility and set
the item as follows. Select the [Advanced] menu – [Reset
Configuration Data], and set it to [Yes]. If the message still
appears, the CPU or baseboard must be replaced. Contact an
office listed in the "Contact Information" of "Start Guide".
The CPU frequency has changed.
Check whether a proper CPU is installed. If the message
appears although it is proper, update the BIOS by using BIOS
Update Utility supplied with the CPU. If the message still
appears after the update, start up BIOS Setup Utility and set the
item as follows. Select the [Advanced] menu – [Reset
Configuration Data], and set it to [Yes]. If the message still
appears, the CPU or baseboard must be replaced. Contact an
office listed in the "Contact Information" of "Start Guide".
The type of installed CPU is different.
Check whether a proper CPU is installed. If the message
appears although it is proper, update the BIOS by using BIOS
Update Utility supplied with the CPU. If the message still
appears after the update, start up BIOS Setup Utility and set the
item as follows. Select the [Advanced] menu – [Reset
Configuration Data], and set it to [Yes]. If the message still
appears, the CPU or baseboard must be replaced. Contact an
office listed in the "Contact Information" of "Start Guide".
It indicates an iRMC error. Turn off the server and turn it back
on. If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".