Message
Diskette drive A error
Incorrect Drive A type - run SETUP
Diskette drive B error
Incorrect Drive B type - run SETUP
System cache error - Cache disabled
Verify CPU Frequency selection in Setup
CPU runtime error (IERR#) detected
Uncorrectable memory error
Memory configuration has changed - Run
SETUP
No usable system memory.
Memory module disabled! This module is no
longer available for the operating system.
No usable CPU
table: List of POST error messages
It indicates a floppy disk drive A error or setting error.
Check whether the floppy disk drive cable is connected
properly. Also check the setting as follows. Start up BIOS Setup
Utility, and select the [Main] menu and check the setting of
[Diskette A].
If the message still appears, the floppy disk drive cable or the
floppy disk drive must be replaced.
It indicates a setting error or baseboard error. Turn off the server
and turn it back on. If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
It indicates a system cache error. Turn off the server and turn it
back on. If the message still appears, check the error log and
replace the CPU if it is faulty. Or the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
It indicates a CPU error. Turn off the server and turn it back on.
If the message still appears, check the error log and replace the
CPU if it is faulty. Or the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
It indicates an installed CPU error. Check the error log and
replace the CPU. If the message still appears, the baseboard or
PCI cards must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
It indicates a memory error. Check the error log and replace the
memory module. If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
It indicates a memory error. The memory size has changed since
the last startup. Check the error log and replace the memory
module. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
It indicates a memory error. No memory is available for the
system. Check the error log and replace the memory module. If
the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide". After the replacement, enable the use of the memory in
BIOS Setup Utility.
It indicates a memory error. Turn off the server, and check
whether the memory modules are installed properly. If the
message still appears, check the error log and replace the
relevant memory module. If the message still appears after the
replacement, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
It indicates an installed CPU error. Replace the CPU. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
After the replacement, enable the use of the CPU in BIOS Setup
Utility.