Troubleshooting
NOTE
• Before performed trouble shooting, be sure to read the "Precautions of ECM Circuit Inspection".
• When measuring circuit voltage, resistance and/or pulse signal at ECM connector, connect the
special tool to ECM and/or the ECM connectors referring to "Inspection of ECM and Its Circuits".
Step
1
MIL power supply check
1) Turn ignition switch to ON position.
Do other warning lights come ON?
2
DTC check
1) Connect scan tool to DLC with ignition switch turned
OFF.
2) Turn ON ignition switch and check DTC in ECM.
Is there DTC(s) U0073 and/or U0121?
3
Combination meter power supply and ground circuit
check
1) Turn ignition switch OFF position.
2) Disconnect connector from combination meter.
3) Check for proper connection to power supply and
ground terminals of combination meter connector.
4) If connections are OK, check that combination meter
circuit is as follows.
• Circuit voltage between combination meter power
supply terminal and vehicle body ground is 10 –14 V.
• Wiring harness resistance of combination meter
ground terminal and vehicle body ground is less than
3 Ω.
Are they in good condition?
4
CAN communication line circuit check
1) Check CAN communication line circuit between control
modules for open, short, high resistance and
connections referring to Step 5 to 10 under
"Troubleshooting for Communication Error with Scan
Tool Using CAN".
Is circuit in good condition?
Action
Engine General Information and Diagnosis:
Yes
Go to Step 2.
Go to applicable DTC
diag. flow.
Go to Step 4.
Substitute a known-
good combination meter
and recheck. If MIL still
remains OFF, substitute
a known-good ECM and
recheck.
1A-53
No
Go to Step 3.
Go to Step 3.
Repair or replace.
Repair or replace.