Coupling Air Temperature Sensor Inspection

CAUTION
!
Do not heat up coupling air temperature
sensor more than 100 °C (212 °F). Otherwise,
coupling air temperature sensor will be
damaged.
• Blow hot air to temperature sensing part (2) of
coupling air temperature sensor (3) using hot air drier
(4) and measure resistance between sensor terminals
while heating air gradually.
If measured resistance does not show such
characteristic as shown, replace air temperature
sensor.
1
4
[D]
(6.00)
(2.56)
[A]
(0.34)
0
20
32
68
[A]: Lower limit
[B]: Normal
[C]: Upper limit
S6RW0D3206007
3
2
[C]
[B]
80
[E]
176
I5RW0A320021-01
[D]: Resistance
[E]: Temperature
1. Temperature gauge

Coupling Assembly Inspection

• Check coupling assembly for oil leakage. If leakage
exists, replace it.
• Measure resistance between "a" terminal and "b"
terminal of coupling connector (1).
If measured resistance is out of specification, check
harness for open or short.
If OK, replace coupling assembly.
Coupling assembly resistance
: 2 – 3 Ω
Differential:
3B-32
S6RW0D3206008
1
"a"
"b"
I5RW0A320064-01