Charging Service Data; Erence - Toyota 1KZ-TE Repair Manual

Fo toyota hilux kzn165 series
Hide thumbs Also See for 1KZ-TE:
Table of Contents

Advertisement

CLICK HERE TO VIEW CHAPTER INDEX
CHARGING
SERVICE DATA
Battery
Specific gravity
Voltage
Drive belt
Deflection
Reference
Alternator
Rated output
Rotor coil resistance
Slip ring diameter
Brush exposed length
IC regulator
Regulating voltage
SERVICE SPECIFICATIONS
Tension
- -
CHARGING
at 20˚C (68˚F)
1.25 - - 1.29
at 20˚C (68˚F)
12.5 - - 12.9 V
New belt
6 - - 8 mm (0.24 - - 0.31 in.)
Used belt
8 - - 12 mm (0.31 - - 0.47 in.)
New belt
400 - - 600 N (41 - - 61 kgf)
Used belt
300 - - 500 N (31 - - 51 kgf)
12 V 70 A
at 20˚C (68˚F)
2.1 - - 2.5 Ω
STD
14.2 mm - - 14.4 mm (0.559 - - 0.567 in.)
Minimum
12.8 mm (0.504 in.)
9.5 - - 11.5 mm (0.374 - - 0.453 in.)
STD
Minimum
1.5 mm (0.059 in.)
13.2 - - 14.8 V
1KZ-TE
Pages From Manual
TO MODEL INDEX
SS- -21
SS0UL- -02
CONTINUED